CVE-2019-5182 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 2.1 LOW | 5.5 MEDIUM |
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file.The destination buffer sp+0x440 is overflowed with the call to sprintf() for any type values that are greater than 1024-len(‘/etc/config-tools/config_interfaces interface=X1 state=enabled config-type=‘) in length. A type value of length 0x3d9 will cause the service to crash. | |||||
CVE-2019-5175 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 7.2 HIGH | 7.8 HIGH |
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1ea28 the extracted type value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled config-type=<contents of type node> using sprintf(). This command is later executed via a call to system(). | |||||
CVE-2019-5174 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 7.2 HIGH | 7.8 HIGH |
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file.At 0x1e9fc the extracted subnetmask value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=enabled subnet-mask=<contents of subnetmask node> using sprintf(). This command is later executed via a call to system(). | |||||
CVE-2019-5155 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 9.0 HIGH | 7.2 HIGH |
An exploitable command injection vulnerability exists in the cloud connectivity feature of WAGO PFC200. An attacker can inject operating system commands into any of the parameter values contained in the firmware update command. This affects WAGO PFC200 Firmware version 03.02.02(14), version 03.01.07(13), and version 03.00.39(12) | |||||
CVE-2019-5173 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 7.2 HIGH | 7.8 HIGH |
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can be used to inject OS commands. An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e9fc the extracted state value from the xml file is used as an argument to /etc/config-tools/config_interfaces interface=X1 state=<contents of state node> using sprintf(). This command is later executed via a call to system(). | |||||
CVE-2019-5172 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 7.2 HIGH | 7.8 HIGH |
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file. At 0x1e840 the extracted ntp value from the xml file is used as an argument to /etc/config-tools/config_sntp time-server-%d=<contents of ntp node> using sprintf(). This command is later executed via a call to system(). This is done in a loop and there is no limit to how many ntp entries will be parsed from the xml file. | |||||
CVE-2019-5179 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 4.6 MEDIUM | 7.8 HIGH |
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file. | |||||
CVE-2019-5178 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 4.6 MEDIUM | 7.8 HIGH |
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file. The destination buffer sp+0x440 is overflowed with the call to sprintf() for any hostname values that are greater than 1024-len(‘/etc/config-tools/change_hostname hostname=‘) in length. A hostname value of length 0x3fd will cause the service to crash. | |||||
CVE-2019-5180 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 4.6 MEDIUM | 7.8 HIGH |
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). An attacker can send a specially crafted packet to trigger the parsing of this cache file. The destination buffer sp+0x440 is overflowed with the call to sprintf() for any ip values that are greater than 1024-len(‘/etc/config-tools/config_interfaces interface=X1 state=enabled ip-address=‘) in length. A ip value of length 0x3da will cause the service to crash. | |||||
CVE-2019-5181 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-17 | 4.6 MEDIUM | 7.8 HIGH |
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). A specially crafted XML cache file written to a specific location on the device can cause a stack buffer overflow, resulting in code execution. An attacker can send a specially crafted packet to trigger the parsing of this cache file. The destination buffer sp+0x440 is overflowed with the call to sprintf() for any subnetmask values that are greater than 1024-len(‘/etc/config-tools/config_interfaces interface=X1 state=enabled subnet-mask=‘) in length. A subnetmask value of length 0x3d9 will cause the service to crash. | |||||
CVE-2019-5168 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-16 | 7.2 HIGH | 7.8 HIGH |
An exploitable command injection vulnerability exists in the iocheckd service ‘I/O-Check’ function of the WAGO PFC 200 version 03.02.02(14). An attacker can send a specially crafted XML cache file At 0x1e8a8 the extracted domainname value from the xml file is used as an argument to /etc/config-tools/edit_dns_server domain-name=<contents of domainname node> using sprintf().This command is later executed via a call to system(). | |||||
CVE-2019-5161 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-13 | 9.0 HIGH | 9.1 CRITICAL |
An exploitable remote code execution vulnerability exists in the Cloud Connectivity functionality of WAGO PFC200 versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). A specially crafted XML file will direct the Cloud Connectivity service to download and execute a shell script with root privileges. | |||||
CVE-2019-5149 | 1 Wago | 4 Pfc100, Pfc100 Firmware, Pfc200 and 1 more | 2020-03-13 | 5.0 MEDIUM | 7.5 HIGH |
The WBM web application on firmwares prior to 03.02.02 and 03.01.07 on the WAGO PFC100 and PFC2000, respectively, runs on a lighttpd web server and makes use of the FastCGI module, which is intended to provide high performance for all Internet applications without the penalties of Web server APIs. However, the default configuration of this module appears to limit the number of concurrent php-cgi processes to two, which can be abused to cause a denial of service of the entire web server. This affects WAGO PFC200 Firmware version 03.00.39(12) and version 03.01.07(13), and WAGO PFC100 Firmware version 03.00.39(12) and version 03.02.02(14). | |||||
CVE-2019-5177 | 1 Wago | 2 Pfc200, Pfc200 Firmware | 2020-03-12 | 2.1 LOW | 5.5 MEDIUM |
An exploitable stack buffer overflow vulnerability vulnerability exists in the iocheckd service ‘I/O-Check’ functionality of WAGO PFC 200 Firmware version 03.02.02(14). The destination buffer sp+0x440 is overflowed with the call to sprintf() for any domainname values that are greater than 1024-len(‘/etc/config-tools/edit_dns_server domain-name=‘) in length. A domainname value of length 0x3fa will cause the service to crash. | |||||
CVE-2019-5082 | 1 Wago | 4 Pfc100, Pfc100 Firmware, Pfc200 and 1 more | 2020-01-22 | 7.5 HIGH | 9.8 CRITICAL |
An exploitable heap buffer overflow vulnerability exists in the iocheckd service I/O-Check functionality of WAGO PFC200 Firmware version 03.01.07(13), WAGO PFC200 Firmware version 03.00.39(12), and WAGO PFC100 Firmware version 03.00.39(12). A specially crafted set of packets can cause a heap buffer overflow, potentially resulting in code execution. An attacker can send unauthenticated packets to trigger this vulnerability. | |||||
CVE-2018-5459 | 1 Wago | 19 750-8202, 750-8202\/025-000, 750-8202\/025-001 and 16 more | 2019-10-09 | 7.5 HIGH | 9.8 CRITICAL |
An Improper Authentication issue was discovered in WAGO PFC200 Series 3S CoDeSys Runtime versions 2.3.X and 2.4.X. An attacker can execute different unauthenticated remote operations because of the CoDeSys Runtime application, which is available via network by default on Port 2455. An attacker could execute some unauthenticated commands such as reading, writing, or deleting arbitrary files, or manipulate the PLC application during runtime by sending specially-crafted TCP packets to Port 2455. | |||||
CVE-2016-9362 | 1 Wago | 7 750-8202, 750-881, 750-xxxx Series Firmware and 4 more | 2017-06-28 | 6.4 MEDIUM | 9.1 CRITICAL |
An issue was discovered in WAGO 750-8202/PFC200 prior to FW04 (released August 2015), WAGO 750-881 prior to FW09 (released August 2016), and WAGO 0758-0874-0000-0111. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to edit and to view settings without authenticating. |