Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Juniper Subscribe
Filtered by product Mx2008
Total 44 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2020-1638 1 Juniper 11 Junos, Junos Os Evolved, Mx10003 and 8 more 2022-01-01 5.0 MEDIUM 7.5 HIGH
The FPC (Flexible PIC Concentrator) of Juniper Networks Junos OS and Junos OS Evolved may restart after processing a specific IPv4 packet. Only packets destined to the device itself, successfully reaching the RE through existing edge and control plane filtering, will be able to cause the FPC restart. When this issue occurs, all traffic via the FPC will be dropped. By continuously sending this specific IPv4 packet, an attacker can repeatedly crash the FPC, causing an extended Denial of Service (DoS) condition. This issue can only occur when processing a specific IPv4 packet. IPv6 packets cannot trigger this issue. This issue affects: Juniper Networks Junos OS on MX Series with MPC10E or MPC11E and PTX10001: 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. Juniper Networks Junos OS Evolved on on QFX5220, and PTX10003 series: 19.2-EVO versions; 19.3-EVO versions; 19.4-EVO versions prior to 19.4R2-EVO. This issue does not affect Junos OS versions prior to 19.2R1. This issue does not affect Junos OS Evolved versions prior to 19.2R1-EVO.
CVE-2020-1633 1 Juniper 16 Junos, Mx10, Mx10000 and 13 more 2021-11-22 3.3 LOW 6.5 MEDIUM
Due to a new NDP proxy feature for EVPN leaf nodes introduced in Junos OS 17.4, crafted NDPv6 packets could transit a Junos device configured as a Broadband Network Gateway (BNG) and reach the EVPN leaf node, causing a stale MAC address entry. This could cause legitimate traffic to be discarded, leading to a Denial of Service (DoS) condition. This issue only affects Junos OS 17.4 and later releases. Prior releases do not support this feature and are unaffected by this vulnerability. This issue only affects IPv6. IPv4 ARP proxy is unaffected by this vulnerability. This issue affects Juniper Networks Junos OS: 17.4 versions prior to 17.4R2-S9, 17.4R3 on MX Series; 18.1 versions prior to 18.1R3-S9 on MX Series; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D33, 18.2X75-D411, 18.2X75-D420, 18.2X75-D60 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S3, 18.3R3 on MX Series; 18.4 versions prior to 18.4R1-S5, 18.4R2-S2, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series.
CVE-2019-0056 1 Juniper 6 Junos, Mx2008, Mx2010 and 3 more 2021-10-28 5.0 MEDIUM 7.5 HIGH
This issue only affects devices with three (3) or more MPC10's installed in a single chassis with OSPF enabled and configured on the device. An Insufficient Resource Pool weakness allows an attacker to cause the device's Open Shortest Path First (OSPF) states to transition to Down, resulting in a Denial of Service (DoS) attack. This attack requires a relatively large number of specific Internet Mixed (IMIXed) types of genuine and valid IPv6 packets to be transferred by the attacker in a relatively short period of time, across three or more PFE's on the device at the same time. Continued receipt of the traffic sent by the attacker will continue to cause OSPF to remain in the Down starting state, or flap between other states and then again to Down, causing a persistent Denial of Service. This attack will affect all IPv4, and IPv6 traffic served by the OSPF routes once the OSPF states transition to Down. This issue affects: Juniper Networks Junos OS on MX480, MX960, MX2008, MX2010, MX2020: 18.1 versions prior to 18.1R2-S4, 18.1R3-S5; 18.1X75 version 18.1X75-D10 and later versions; 18.2 versions prior to 18.2R1-S5, 18.2R2-S3, 18.2R3; 18.2X75 versions prior to 18.2X75-D50; 18.3 versions prior to 18.3R1-S4, 18.3R2, 18.3R3; 18.4 versions prior to 18.4R1-S2, 18.4R2.
CVE-2021-31379 1 Juniper 18 Junos, Mx10, Mx10000 and 15 more 2021-10-27 4.3 MEDIUM 7.5 HIGH
An Incorrect Behavior Order vulnerability in the MAP-E automatic tunneling mechanism of Juniper Networks Junos OS allows an attacker to send certain malformed IPv4 or IPv6 packets to cause a Denial of Service (DoS) to the PFE on the device which is disabled as a result of the processing of these packets. Continued receipt and processing of these malformed IPv4 or IPv6 packets will create a sustained Denial of Service (DoS) condition. This issue only affects MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. An indicator of compromise is the output: FPC ["FPC ID" # e.g. "0"] PFE #{PFE ID # e.g. "1"] : Fabric Disabled Example: FPC 0 PFE #1 : Fabric Disabled when using the command: show chassis fabric fpcs An example of a healthy result of the command use would be: user@device-re1> show chassis fabric fpcs Fabric management FPC state: FPC 0 PFE #0 Plane 0: Plane enabled Plane 1: Plane enabled Plane 2: Plane enabled Plane 3: Plane enabled Plane 4: Plane enabled Plane 5: Plane enabled Plane 6: Plane enabled Plane 7: Plane enabled This issue affects: Juniper Networks Junos OS on MX Series with MPC 7/8/9/10/11 cards, when MAP-E IP reassembly is enabled on these cards. 17.2 version 17.2R1 and later versions; 17.3 versions prior to 17.3R3-S9; 17.4 versions prior to 17.4R2-S12, 17.4R3-S3; 18.1 versions prior to 18.1R3-S11; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3; 18.3 versions prior to 18.3R2-S4, 18.3R3-S1; 18.4 versions prior to 18.4R1-S8, 18.4R2-S5, 18.4R3; 19.1 versions prior to 19.1R1-S6, 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R1-S5, 19.2R2; 19.3 versions prior to 19.3R2-S5, 19.3R3. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R1.
CVE-2021-31369 1 Juniper 18 Junos, Mx10, Mx10000 and 15 more 2021-10-26 4.3 MEDIUM 5.3 MEDIUM
On MX Series platforms with MS-MPC/MS-MIC, an Allocation of Resources Without Limits or Throttling vulnerability in Juniper Networks Junos OS allows an unauthenticated network attacker to cause a partial Denial of Service (DoS) with a high rate of specific traffic. If a Class of Service (CoS) rule is attached to the service-set and a high rate of specific traffic is processed by this service-set, for some of the other traffic which has services applied and is being processed by this MS-MPC/MS-MIC drops will be observed. Continued receipted of this high rate of specific traffic will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS on MX Series with MS-MPC/MS-MIC: All versions prior to 17.4R3-S5; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S7, 19.3R3-S3; 19.4 versions prior to 19.4R3-S5; 20.1 versions prior to 20.1R2-S2, 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2-S1, 20.4R3; 21.1 versions prior to 21.1R1-S1, 21.1R2.
CVE-2021-31351 1 Juniper 18 Junos, Mx10, Mx10000 and 15 more 2021-10-25 5.0 MEDIUM 7.5 HIGH
An Improper Check for Unusual or Exceptional Conditions in packet processing on the MS-MPC/MS-MIC utilized by Juniper Networks Junos OS allows a malicious attacker to send a specific packet, triggering the MS-MPC/MS-MIC to reset, causing a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue only affects specific versions of Juniper Networks Junos OS on MX Series: 17.3R3-S11; 17.4R2-S13; 17.4R3 prior to 17.4R3-S5; 18.1R3-S12; 18.2R2-S8, 18.2R3-S7, 18.2R3-S8; 18.3R3-S4; 18.4R3-S7; 19.1R3-S4, 19.1R3-S5; 19.2R1-S6; 19.3R3-S2; 19.4R2-S4, 19.4R2-S5; 19.4R3-S2; 20.1R2-S1; 20.2R2-S2, 20.2R2-S3, 20.2R3; 20.3R2, 20.3R2-S1; 20.4R1, 20.4R1-S1, 20.4R2; 21.1R1; This issue does not affect any version of Juniper Networks Junos OS prior to 15.1X49-D240;
CVE-2021-31366 1 Juniper 17 Junos, Mx10, Mx10003 and 14 more 2021-10-25 3.3 LOW 6.5 MEDIUM
An Unchecked Return Value vulnerability in the authd (authentication daemon) of Juniper Networks Junos OS on MX Series configured for subscriber management / BBE allows an adjacent attacker to cause a crash by sending a specific username. This impacts authentication, authorization, and accounting (AAA) services on the MX devices and leads to a Denial of Service (DoS) condition. Continued receipted of these PPP login request will create a sustained Denial of Service (DoS) condition. This issue affects: Juniper Networks Junos OS 15.1 versions prior to 15.1R7-S9; 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R3-S9; 19.1 versions prior to 19.1R3-S6; 19.2 versions prior to 19.2R1-S7, 19.2R3-S3; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S1; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2.
CVE-2020-1651 1 Juniper 16 Junos, Mx10, Mx10000 and 13 more 2021-10-19 3.3 LOW 6.5 MEDIUM
On Juniper Networks MX series, receipt of a stream of specific Layer 2 frames may cause a memory leak resulting in the packet forwarding engine (PFE) on the line card to crash and restart, causing traffic interruption. By continuously sending this stream of specific layer 2 frame, an attacker connected to the same broadcast domain can repeatedly crash the PFE, causing a prolonged Denial of Service (DoS). This issue affects Juniper Networks Junos OS on MX Series: 17.2 versions prior to 17.2R3-S4; 17.2X75 versions prior to 17.2X75-D105.19; 17.3 versions prior to 17.3R3-S7; 17.4 versions prior to 17.4R1-S3, 17.4R2; 18.1 versions prior to 18.1R2. This issue does not affect Juniper Networks Junos OS releases prior to 17.2R1.
CVE-2021-0290 1 Juniper 26 Ex9200, Ex9204, Ex9208 and 23 more 2021-07-29 3.3 LOW 6.5 MEDIUM
Improper Handling of Exceptional Conditions in Ethernet interface frame processing of Juniper Networks Junos OS allows an attacker to send specially crafted frames over the local Ethernet segment, causing the interface to go into a down state, resulting in a Denial of Service (DoS) condition. The interface does not recover on its own and the FPC must be reset manually. Continued receipt and processing of these frames will create a sustained Denial of Service (DoS) condition. This issue is platform-specific and affects the following platforms and line cards: * MPC7E/8E/9E and MPC10E on MX240, MX480, MX960, MX2008, MX2010, and MX2020 * MX204, MX10003, MX10008, MX10016 * EX9200, EX9251 * SRX4600 No other products or platforms are affected by this vulnerability. An indication of this issue occurring can be seen in the system log messages, as shown below: user@host> show log messages | match "Failed to complete DFE tuning" fpc4 smic_phy_dfe_tuning_state: et-4/1/6 - Failed to complete DFE tuning (count 3) and interface will be in a permanently down state: user@host> show interfaces et-4/1/6 terse Interface Admin Link Proto Local Remote et-4/1/6 up down et-4/1/6.0 up down aenet --> ae101.0 This issue affects Juniper Networks Junos OS: 16.1 versions prior to 16.1R7-S7 on MX Series; 17.1R1 and later versions prior to 17.2R3-S3 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S11, 17.4R3-S1 on MX Series, SRX4600; 18.1 versions prior to 18.1R3-S10 on MX Series, EX9200 Series, SRX4600; 18.2 versions prior to 18.2R3-S3 on MX Series, EX9200 Series, SRX4600; 18.3 versions prior to 18.3R3-S1 on MX Series, EX9200 Series, SRX4600; 18.4 versions prior to 18.4R2-S3, 18.4R3 on MX Series, EX9200 Series, SRX4600; 19.1 versions prior to 19.1R2-S1, 19.1R3 on MX Series, EX9200 Series, SRX4600; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series, EX9200 Series, SRX4600; 19.3 versions prior to 19.3R2 on MX Series, EX9200 Series, SRX4600. This issue does not affect Juniper Networks Junos OS versions prior to 16.1R1.
CVE-2021-0288 1 Juniper 26 Ex9200, Ex9204, Ex9208 and 23 more 2021-07-29 3.3 LOW 6.5 MEDIUM
A vulnerability in the processing of specific MPLS packets in Juniper Networks Junos OS on MX Series and EX9200 Series devices with Trio-based MPCs (Modular Port Concentrators) may cause FPC to crash and lead to a Denial of Service (DoS) condition. Continued receipt of this packet will sustain the Denial of Service (DoS) condition. This issue only affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines). This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R2-S13, 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R2-S8, 18.4R3-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R1-S4, 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2;
CVE-2021-0289 1 Juniper 229 Acx1000, Acx1100, Acx2000 and 226 more 2021-07-28 2.9 LOW 5.3 MEDIUM
When user-defined ARP Policer is configured and applied on one or more Aggregated Ethernet (AE) interface units, a Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability between the Device Control Daemon (DCD) and firewall process (dfwd) daemons of Juniper Networks Junos OS allows an attacker to bypass the user-defined ARP Policer. In this particular case the User ARP policer is replaced with default ARP policer. To review the desired ARP Policers and actual state one can run the command "show interfaces <> extensive" and review the output. See further details below. An example output is: show interfaces extensive | match policer Policer: Input: __default_arp_policer__ <<< incorrect if user ARP Policer was applied on an AE interface and the default ARP Policer is displayed Policer: Input: jtac-arp-ae5.317-inet-arp <<< correct if user ARP Policer was applied on an AE interface For all platforms, except SRX Series: This issue affects Juniper Networks Junos OS: All versions 5.6R1 and all later versions prior to 18.4 versions prior to 18.4R2-S9, 18.4R3-S9 with the exception of 15.1 versions 15.1R7-S10 and later versions; 19.4 versions prior to 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2; This issue does not affect Juniper Networks Junos OS versions prior to 5.6R1. On SRX Series this issue affects Juniper Networks Junos OS: 18.4 versions prior to 18.4R2-S9, 18.4R3-S9; 19.4 versions prior to 19.4R3-S4; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R3-S2; 20.3 version 20.3R1 and later versions; 20.4 versions prior to 20.4R3; 21.1 versions prior to 21.1R2. This issue does not affect 18.4 versions prior to 18.4R1 on SRX Series. This issue does not affect Junos OS Evolved.
CVE-2019-0063 1 Juniper 18 Junos, Mx10, Mx10003 and 15 more 2021-07-21 4.3 MEDIUM 7.5 HIGH
When an MX Series Broadband Remote Access Server (BRAS) is configured as a Broadband Network Gateway (BNG) with DHCPv6 enabled, jdhcpd might crash when receiving a specific crafted DHCP response message on a subscriber interface. The daemon automatically restarts without intervention, but continuous receipt of specific crafted DHCP messages will repeatedly crash jdhcpd, leading to an extended Denial of Service (DoS) condition. This issue only affects systems configured with DHCPv6 enabled. DHCPv4 is unaffected by this issue. This issue affects Juniper Networks Junos OS: 15.1 versions prior to 15.1R7-S5 on MX Series; 16.1 versions prior to 16.1R7-S5 on MX Series; 16.2 versions prior to 16.2R2-S10 on MX Series; 17.1 versions prior to 17.1R3-S1 on MX Series; 17.2 versions prior to 17.2R3-S2 on MX Series; 17.3 versions prior to 17.3R3-S6 on MX Series; 17.4 versions prior to 17.4R2-S5, 17.4R3 on MX Series; 18.1 versions prior to 18.1R3-S6 on MX Series; 18.2 versions prior to 18.2R2-S4, 18.2R3 on MX Series; 18.2X75 versions prior to 18.2X75-D50 on MX Series; 18.3 versions prior to 18.3R1-S5, 18.3R3 on MX Series; 18.4 versions prior to 18.4R2 on MX Series; 19.1 versions prior to 19.1R1-S2, 19.1R2 on MX Series.
CVE-2020-1655 1 Juniper 16 Junos, Mx10, Mx10000 and 13 more 2021-07-21 5.0 MEDIUM 5.3 MEDIUM
When a device running Juniper Networks Junos OS with MPC7, MPC8, or MPC9 line cards installed and the system is configured for inline IP reassembly, used by L2TP, MAP-E, GRE, and IPIP, the packet forwarding engine (PFE) will become disabled upon receipt of large packets requiring fragmentation, generating the following error messages: [LOG: Err] MQSS(0): WO: Packet Error - Error Packets 1, Connection 29 [LOG: Err] eachip_hmcif_rx_intr_handler(7259): EA[0:0]: HMCIF Rx: Injected checksum error detected on WO response - Chunk Address 0x0 [LOG: Err] MQSS(0): DRD: RORD1: CMD reorder ID error - Command 11, Reorder ID 1838, QID 0 [LOG: Err] MQSS(0): DRD: UNROLL0: HMC chunk length error in stage 5 - Chunk Address: 0x4321f3 [LOG: Err] MQSS(0): DRD: UNROLL0: HMC chunk address error in stage 5 - Chunk Address: 0x0 [LOG: Notice] Error: /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc), scope: pfe, category: functional, severity: major, module: MQSS(0), type: DRD_RORD_ENG_INT: CMD FSM State Error [LOG: Notice] Performing action cmalarm for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major [LOG: Notice] Performing action get-state for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major [LOG: Notice] Performing action disable-pfe for error /fpc/8/pfe/0/cm/0/MQSS(0)/0/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(0) with scope: pfe category: functional level: major By continuously sending fragmented packets that cannot be reassembled, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue affects Juniper Networks Junos OS: 17.2 versions prior to 17.2R3-S4 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S10, 17.4R3-S2 on MX Series; 18.1 versions prior to 18.1R3-S10 on MX Series; 18.2 versions prior to 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D41, 18.2X75-D430, 18.2X75-D65 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S1 on MX Series; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S5, 19.1R2-S1, 19.1R3 on MX Series; 19.2 versions prior to 19.2R1-S4, 19.2R2 on MX Series; 19.3 versions prior to 19.3R2-S2, 19.3R3 on MX Series. This issue is specific to inline IP reassembly, introduced in Junos OS 17.2. Versions of Junos OS prior to 17.2 are unaffected by this vulnerability.
CVE-2020-1650 1 Juniper 16 Junos, Mx10, Mx10000 and 13 more 2021-07-21 5.0 MEDIUM 7.5 HIGH
On Juniper Networks Junos MX Series with service card configured, receipt of a stream of specific packets may crash the MS-PIC component on MS-MIC or MS-MPC. By continuously sending these specific packets, an attacker can repeatedly bring down MS-PIC on MS-MIC/MS-MPC causing a prolonged Denial of Service. This issue affects MX Series devices using MS-PIC, MS-MIC or MS-MPC service cards with any service configured. This issue affects Juniper Networks Junos OS on MX Series: 17.2R2-S7; 17.3R3-S4, 17.3R3-S5; 17.4R2-S4 and the subsequent SRs (17.4R2-S5, 17.4R2-S6, etc.); 17.4R3; 18.1R3-S3, 18.1R3-S4, 18.1R3-S5, 18.1R3-S6, 18.1R3-S7, 18.1R3-S8; 18.2R3, 18.2R3-S1, 18.2R3-S2; 18.3R2 and the SRs based on 18.3R2; 18.4R2 and the SRs based on 18.4R2; 19.1R1 and the SRs based on 19.1R1; 19.2R1 and the SRs based on 19.2R1; 19.3R1 and the SRs based on 19.3R1.
CVE-2020-1649 1 Juniper 16 Junos, Mx10, Mx10000 and 13 more 2021-07-21 5.0 MEDIUM 7.5 HIGH
When a device running Juniper Networks Junos OS with MPC7, MPC8, or MPC9 line cards installed and the system is configured for inline IP reassembly, used by L2TP, MAP-E, GRE, and IPIP, the packet forwarding engine (PFE) will become disabled upon receipt of small fragments requiring reassembly, generating the following error messages: [LOG: Err] MQSS(2): WO: Packet Error - Error Packets 1, Connection 29 [LOG: Err] eachip_hmcif_rx_intr_handler(7259): EA[2:0]: HMCIF Rx: Injected checksum error detected on WO response - Chunk Address 0x0 [LOG: Err] MQSS(2): DRD: RORD1: CMD reorder ID error - Command 11, Reorder ID 1960, QID 0 [LOG: Err] MQSS(2): DRD: UNROLL0: HMC chunk address error in stage 5 - Chunk Address: 0xc38fb1 [LOG: Notice] Error: /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc), scope: pfe, category: functional, severity: major, module: MQSS(2), type: DRD_RORD_ENG_INT: CMD FSM State Error [LOG: Notice] Performing action cmalarm for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action get-state for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major [LOG: Notice] Performing action disable-pfe for error /fpc/0/pfe/0/cm/0/MQSS(2)/2/MQSS_CMERROR_DRD_RORD_ENG_INT_REG_CMD_FSM_STATE_ERR (0x2203cc) in module: MQSS(2) with scope: pfe category: functional level: major By continuously sending fragmented packets that cannot be reassembled, an attacker can repeatedly disable the PFE causing a sustained Denial of Service (DoS). This issue affects Juniper Networks Junos OS: 17.2 versions prior to 17.2R3-S4 on MX Series; 17.3 versions prior to 17.3R3-S8 on MX Series; 17.4 versions prior to 17.4R2-S9, 17.4R3-S1 on MX Series; 18.1 versions prior to 18.1R3-S10 on MX Series; 18.2 versions prior to 18.2R2-S6, 18.2R3-S3 on MX Series; 18.2X75 versions prior to 18.2X75-D34, 18.2X75-D41, 18.2X75-D53, 18.2X75-D65, 18.2X75-D430 on MX Series; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S2 on MX Series; 18.4 versions prior to 18.4R1-S6, 18.4R2-S4, 18.4R3 on MX Series; 19.1 versions prior to 19.1R1-S4, 19.1R2-S1, 19.1R3 on MX Series; 19.2 versions prior to 19.2R1-S3, 19.2R2 on MX Series; 19.3 versions prior to 19.3R2-S2, 19.3R3 on MX Series. This issue is specific to inline IP reassembly, introduced in Junos OS 17.2. Versions of Junos OS prior to 17.2 are unaffected by this vulnerability.
CVE-2020-1608 1 Juniper 17 Junos, Mx10, Mx10003 and 14 more 2021-07-21 7.8 HIGH 7.5 HIGH
Receipt of a specific MPLS or IPv6 packet on the core facing interface of an MX Series device configured for Broadband Edge (BBE) service may trigger a kernel crash (vmcore), causing the device to reboot. The issue is specific to the processing of packets destined to BBE clients connected to MX Series subscriber management platforms. This issue affects MX Series running Juniper Networks Junos OS: 17.2 versions starting from17.2R2-S6, 17.2R3 and later releases, prior to 17.2R3-S3; 17.3 versions starting from 17.3R2-S4, 17.3R3-S2 and later releases, prior to 17.3R2-S5, 17.3R3-S5; 17.4 versions starting from 17.4R2 and later releases, prior to 17.4R2-S7,17.4R3; 18.1 versions starting from 18.1R2-S3, 18.1R3 and later releases, prior to 18.1R3-S6; 18.2 versions starting from18.2R1-S1, 18.2R2 and later releases, prior to 18.2R3-S2; 18.2X75 versions prior to 18.2X75-D51, 18.2X75-D60; 18.3 versions prior to 18.3R3; 18.4 versions prior to 18.4R2; 19.1 versions prior to 19.1R1-S3, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2. This issue does not affect Juniper Networks Junos OS versions prior to 17.2R2-S6.
CVE-2019-0065 1 Juniper 18 Junos, Mx10, Mx10003 and 15 more 2021-07-21 4.3 MEDIUM 7.5 HIGH
On MX Series, when the SIP ALG is enabled, receipt of a certain malformed SIP packet may crash the MS-PIC component on MS-MIC or MS-MPC. By continuously sending a crafted SIP packet, an attacker can repeatedly bring down MS-PIC on MS-MIC/MS-MPC causing a sustained Denial of Service. This issue affects Juniper Networks Junos OS on MX Series: 16.1 versions prior to 16.1R7-S5; 16.2 versions prior to 16.2R2-S11; 17.1 versions prior to 17.1R3; 17.2 versions prior to 17.2R3-S3; 17.3 versions prior to 17.3R3-S6 ; 17.4 versions prior to 17.4R2-S8, 17.4R3; 18.1 versions prior to 18.1R3-S3; 18.2 versions prior to 18.2R3; 18.3 versions prior to 18.3R2; 18.4 versions prior to 18.4R2.
CVE-2021-0264 1 Juniper 21 Junos, Junos Os Evolved, Mx10 and 18 more 2021-04-30 5.0 MEDIUM 7.5 HIGH
A vulnerability in the processing of traffic matching a firewall filter containing a syslog action in Juniper Networks Junos OS on MX Series with MPC10/MPC11 cards installed, PTX10003 and PTX10008 Series devices, will cause the line card to crash and restart, creating a Denial of Service (DoS). Continued receipt and processing of packets matching the firewall filter can create a sustained Denial of Service (DoS) condition. When traffic hits the firewall filter, configured on lo0 or any physical interface on the line card, containing a term with a syslog action (e.g. 'term <name> then syslog'), the affected line card will crash and restart, impacting traffic processing through the ports of the line card. This issue only affects MX Series routers with MPC10 or MPC11 line cards, and PTX10003 or PTX10008 Series packet transport routers. No other platforms or models of line cards are affected by this issue. Note: This issue has also been identified and described in technical service bulletin TSB17931 (login required). This issue affects: Juniper Networks Junos OS on MX Series: 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S2, 20.2R3; 20.3 versions prior to 20.3R3; 20.4 versions prior to 20.4R2. Juniper Networks Junos OS Evolved on PTX10003, PTX10008: All versions prior to 20.4R2-EVO. This issue does not affect Juniper Networks Junos OS versions prior to 19.3R1.
CVE-2021-0238 1 Juniper 15 Junos, Mx10, Mx10000 and 12 more 2021-04-29 2.1 LOW 5.5 MEDIUM
When a MX Series is configured as a Broadband Network Gateway (BNG) based on Layer 2 Tunneling Protocol (L2TP), executing certain CLI command may cause the system to run out of disk space, excessive disk usage may cause other complications. An administrator can use the following CLI command to monitor the available disk space: user@device> show system storage Filesystem Size Used Avail Capacity Mounted on /dev/gpt/junos 19G 18G 147M 99% /.mount <<<<< running out of space tmpfs 21G 16K 21G 0% /.mount/tmp tmpfs 5.3G 1.7M 5.3G 0% /.mount/mfs This issue affects Juniper Networks Junos OS on MX Series: 17.3R1 and later versions prior to 17.4R3-S5, 18.1 versions prior to 18.1R3-S13, 18.2 versions prior to 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R3-S7; 19.1 versions prior to 19.1R3-S4; 19.2 versions prior to 19.2R1-S6, 19.2R3-S2; 19.3 versions prior to 19.3R3-S2; 19.4 versions prior to 19.4R2-S4, 19.4R3-S2; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R1-S1, 20.4R2; This issue does not affect Juniper Networks Junos OS versions prior to 17.3R1.
CVE-2021-0251 1 Juniper 17 Junos, Mx10, Mx10003 and 14 more 2021-04-27 5.0 MEDIUM 8.6 HIGH
A NULL Pointer Dereference vulnerability in the Captive Portal Content Delivery (CPCD) services daemon (cpcd) of Juniper Networks Junos OS on MX Series with MS-PIC, MS-SPC3, MS-MIC or MS-MPC allows an attacker to send malformed HTTP packets to the device thereby causing a Denial of Service (DoS), crashing the Multiservices PIC Management Daemon (mspmand) process thereby denying users the ability to login, while concurrently impacting other mspmand services and traffic through the device. Continued receipt and processing of these malformed packets will create a sustained Denial of Service (DoS) condition. While the Services PIC is restarting, all PIC services will be bypassed until the Services PIC completes its boot process. An attacker sending these malformed HTTP packets to the device who is not part of the Captive Portal experience is not able to exploit this issue. This issue is not applicable to MX RE-based CPCD platforms. This issue affects: Juniper Networks Junos OS on MX Series 17.3 version 17.3R1 and later versions prior to 17.4 versions 17.4R2-S9, 17.4R3-S2; 18.1 versions prior to 18.1R3-S9; 18.2 versions prior to 18.2R3-S3; 18.3 versions prior to 18.3R3-S1; 18.4 versions prior to 18.4R3; 19.1 versions prior to 19.1R2-S2, 19.1R3; 19.2 versions prior to 19.2R2; 19.3 versions prior to 19.3R3. This issue does not affect: Juniper Networks Junos OS versions prior to 17.3R1.