Vulnerabilities (CVE)

Join the Common Vulnerabilities and Exposures (CVE) community and start to get notified about new vulnerabilities.

Filtered by vendor Schneider-electric Subscribe
Filtered by product Interactive Graphical Scada System
Total 42 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2021-22754 1 Schneider-electric 1 Interactive Graphical Scada System 2021-06-15 6.8 MEDIUM 7.8 HIGH
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22758 1 Schneider-electric 1 Interactive Graphical Scada System 2021-06-15 6.8 MEDIUM 7.8 HIGH
A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22750 1 Schneider-electric 1 Interactive Graphical Scada System 2021-06-15 6.8 MEDIUM 7.8 HIGH
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22751 1 Schneider-electric 1 Interactive Graphical Scada System 2021-06-15 6.8 MEDIUM 7.8 HIGH
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2021-22752 1 Schneider-electric 1 Interactive Graphical Scada System 2021-06-15 6.8 MEDIUM 7.8 HIGH
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.
CVE-2021-22757 1 Schneider-electric 1 Interactive Graphical Scada System 2021-06-15 6.8 MEDIUM 7.8 HIGH
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22756 1 Schneider-electric 1 Interactive Graphical Scada System 2021-06-15 6.8 MEDIUM 7.8 HIGH
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22755 1 Schneider-electric 1 Interactive Graphical Scada System 2021-06-15 6.8 MEDIUM 7.8 HIGH
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied data, when a malicious CGF file is imported to IGSS Definition.
CVE-2021-22710 1 Schneider-electric 1 Interactive Graphical Scada System 2021-03-18 9.3 HIGH 7.8 HIGH
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2021-22711 1 Schneider-electric 1 Interactive Graphical Scada System 2021-03-17 9.3 HIGH 7.8 HIGH
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data.
CVE-2021-22709 1 Schneider-electric 1 Interactive Graphical Scada System 2021-03-17 9.3 HIGH 7.8 HIGH
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2021-22712 1 Schneider-electric 1 Interactive Graphical Scada System 2021-03-17 9.3 HIGH 7.8 HIGH
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.
CVE-2020-7553 1 Schneider-electric 1 Interactive Graphical Scada System 2021-03-15 6.8 MEDIUM 7.8 HIGH
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7550 1 Schneider-electric 1 Interactive Graphical Scada System 2021-02-01 6.8 MEDIUM 7.8 HIGH
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7554 1 Schneider-electric 1 Interactive Graphical Scada System 2021-02-01 6.8 MEDIUM 7.8 HIGH
A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7556 1 Schneider-electric 1 Interactive Graphical Scada System 2021-02-01 6.8 MEDIUM 7.8 HIGH
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7557 1 Schneider-electric 1 Interactive Graphical Scada System 2021-02-01 6.8 MEDIUM 7.8 HIGH
A CWE-125 Out-of-bounds Read vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7558 1 Schneider-electric 1 Interactive Graphical Scada System 2021-02-01 6.8 MEDIUM 7.8 HIGH
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2020-7555 1 Schneider-electric 1 Interactive Graphical Scada System 2021-01-29 6.8 MEDIUM 7.8 HIGH
A CWE-787 Out-of-bounds Write vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
CVE-2017-6033 1 Schneider-electric 1 Interactive Graphical Scada System 2019-10-09 6.8 MEDIUM 7.8 HIGH
A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path.