Filtered by vendor Siemens
Subscribe
Total
1529 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2021-22930 | 4 Debian, Netapp, Nodejs and 1 more | 4 Debian Linux, Nextgen Api, Node.js and 1 more | 2022-11-03 | 7.5 HIGH | 9.8 CRITICAL |
Node.js before 16.6.0, 14.17.4, and 12.22.4 is vulnerable to a use after free attack where an attacker might be able to exploit the memory corruption, to change process behavior. | |||||
CVE-2021-22940 | 5 Debian, Netapp, Nodejs and 2 more | 7 Debian Linux, Nextgen Api, Node.js and 4 more | 2022-11-03 | 5.0 MEDIUM | 7.5 HIGH |
Node.js before 16.6.1, 14.17.5, and 12.22.5 is vulnerable to a use after free attack where an attacker might be able to exploit the memory corruption, to change process behavior. | |||||
CVE-2022-23990 | 6 Debian, Fedoraproject, Libexpat Project and 3 more | 6 Debian Linux, Fedora, Libexpat and 3 more | 2022-10-31 | 5.0 MEDIUM | 7.5 HIGH |
Expat (aka libexpat) before 2.4.4 has an integer overflow in the doProlog function. | |||||
CVE-2022-0155 | 2 Follow-redirects Project, Siemens | 2 Follow-redirects, Sinec Ins | 2022-10-28 | 4.3 MEDIUM | 6.5 MEDIUM |
follow-redirects is vulnerable to Exposure of Private Personal Information to an Unauthorized Actor | |||||
CVE-2017-9946 | 1 Siemens | 4 Apogee Pxc Bacnet Automation Controller, Apogee Pxc Bacnet Automation Controller Firmware, Talon Tc Bacnet Automation Controller and 1 more | 2022-10-28 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device. | |||||
CVE-2017-9947 | 1 Siemens | 3 Apogee Pxc Bacnet Automation Controller, Apogee Pxc Bacnet Automation Controller Firmware, Talon Tc Bacnet Automation Controller | 2022-10-28 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices. | |||||
CVE-2021-34798 | 8 Apache, Broadcom, Debian and 5 more | 18 Http Server, Brocade Fabric Operating System Firmware, Debian Linux and 15 more | 2022-10-28 | 5.0 MEDIUM | 7.5 HIGH |
Malformed requests may cause the server to dereference a NULL pointer. This issue affects Apache HTTP Server 2.4.48 and earlier. | |||||
CVE-2022-34465 | 1 Siemens | 2 Parasolid, Simcenter Femap | 2022-10-27 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420) | |||||
CVE-2021-33723 | 1 Siemens | 1 Sinec Nms | 2022-10-27 | 4.0 MEDIUM | 6.5 MEDIUM |
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker could change the user profile of any user without proper authorization. With this, the attacker could change the password of any user in the affected system. | |||||
CVE-2021-37183 | 1 Siemens | 1 Sinema Remote Connect Server | 2022-10-27 | 3.3 LOW | 6.5 MEDIUM |
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software allows sending send-to-sleep notifications to the managed devices. An unauthenticated attacker in the same network of the affected system can abuse these notifications to cause a Denial-of-Service condition in the managed devices. | |||||
CVE-2021-37175 | 1 Siemens | 20 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000 Firmware, Ruggedcom Rox Rx1400 and 17 more | 2022-10-27 | 5.0 MEDIUM | 5.3 MEDIUM |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The affected devices do not properly handle permissions to traverse the file system. If exploited, an attacker could gain access to an overview of the complete file system on the affected devices. | |||||
CVE-2021-34307 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2022-10-27 | 4.3 MEDIUM | 5.5 MEDIUM |
A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Tiff_Loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13343) | |||||
CVE-2021-34326 | 1 Siemens | 3 Jt2go, Solid Edge, Teamcenter Visualization | 2022-10-27 | 6.8 MEDIUM | 7.8 HIGH |
A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13422) | |||||
CVE-2021-33713 | 1 Siemens | 1 Jt Utilities | 2022-10-27 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a hash function is called with an incorrect argument leading the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application. | |||||
CVE-2021-33715 | 1 Siemens | 1 Jt Utilities | 2022-10-25 | 2.1 LOW | 5.5 MEDIUM |
A vulnerability has been identified in JT Utilities (All versions < V13.0.2.0). When parsing specially crafted JT files, a race condition could cause an object to be released before being operated on, leading to NULL pointer deference condition and causing the application to crash. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application. | |||||
CVE-2021-27385 | 1 Siemens | 35 Simatic Hmi Comfort Outdoor Panels 15\", Simatic Hmi Comfort Outdoor Panels 15\" Firmware, Simatic Hmi Comfort Outdoor Panels 7\" and 32 more | 2022-10-25 | 5.0 MEDIUM | 7.5 HIGH |
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. | |||||
CVE-2021-39135 | 3 Npmjs, Oracle, Siemens | 4 Arborist, Npm, Graalvm and 1 more | 2022-10-25 | 4.4 MEDIUM | 7.8 HIGH |
`@npmcli/arborist`, the library that calculates dependency trees and manages the node_modules folder hierarchy for the npm command line interface, aims to guarantee that package dependency contracts will be met, and the extraction of package contents will always be performed into the expected folder. This is accomplished by extracting package contents into a project's `node_modules` folder. If the `node_modules` folder of the root project or any of its dependencies is somehow replaced with a symbolic link, it could allow Arborist to write package dependencies to any arbitrary location on the file system. Note that symbolic links contained within package artifact contents are filtered out, so another means of creating a `node_modules` symbolic link would have to be employed. 1. A `preinstall` script could replace `node_modules` with a symlink. (This is prevented by using `--ignore-scripts`.) 2. An attacker could supply the target with a git repository, instructing them to run `npm install --ignore-scripts` in the root. This may be successful, because `npm install --ignore-scripts` is typically not capable of making changes outside of the project directory, so it may be deemed safe. This is patched in @npmcli/arborist 2.8.2 which is included in npm v7.20.7 and above. For more information including workarounds please see the referenced GHSA-gmw6-94gg-2rc2. | |||||
CVE-2021-22649 | 2 Luxion, Siemens | 8 Keyshot, Keyshot Network Rendering, Keyshot Viewer and 5 more | 2022-10-25 | 6.8 MEDIUM | 7.8 HIGH |
Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 have multiple NULL pointer dereference issues while processing project files, which may allow an attacker to execute arbitrary code. | |||||
CVE-2021-22883 | 5 Fedoraproject, Netapp, Nodejs and 2 more | 9 Fedora, E-series Performance Analyzer, Node.js and 6 more | 2022-10-24 | 7.8 HIGH | 7.5 HIGH |
Node.js before 10.24.0, 12.21.0, 14.16.0, and 15.10.0 is vulnerable to a denial of service attack when too many connection attempts with an 'unknownProtocol' are established. This leads to a leak of file descriptors. If a file descriptor limit is configured on the system, then the server is unable to accept new connections and prevent the process also from opening, e.g. a file. If no file descriptor limit is configured, then this lead to an excessive memory usage and cause the system to run out of memory. | |||||
CVE-2022-2069 | 1 Siemens | 2 Jt2go, Teamcenter Visualization | 2022-10-21 | N/A | 7.8 HIGH |
The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process. |