Total
1397 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2018-19450 | 2 Foxitsoftware, Microsoft | 2 Foxit Pdf Sdk Activex, Windows | 2019-06-18 | 6.8 MEDIUM | 7.8 HIGH |
A command injection can occur for specially crafted PDF files in Foxit Reader SDK (ActiveX) 5.4.0.1031 when parsing a launch action. An attacker can leverage this to gain remote code execution. | |||||
CVE-2009-5157 | 1 Linksys | 2 Wag54g2, Wag54g2 Firmware | 2019-06-17 | 9.0 HIGH | 8.8 HIGH |
On Linksys WAG54G2 1.00.10 devices, there is authenticated command injection via shell metacharacters in the setup.cgi c4_ping_ipaddr variable. | |||||
CVE-2010-5330 | 1 Ui | 1 Airos | 2019-06-14 | 5.0 MEDIUM | 9.8 CRITICAL |
On certain Ubiquiti devices, Command Injection exists via a GET request to stainfo.cgi (aka Show AP info) because the ifname variable is not sanitized, as demonstrated by shell metacharacters. The fixed version is v4.0.1 for 802.11 ISP products, v5.3.5 for AirMax ISP products, and v5.4.5 for AirSync firmware. For example, Nanostation5 (Air OS) is affected. | |||||
CVE-2016-10760 | 1 Seowonintech | 8 Swr-300a, Swr-300a Firmware, Swr-300b and 5 more | 2019-06-12 | 10.0 HIGH | 9.8 CRITICAL |
On Seowon Intech routers, there is a Command Injection vulnerability in diagnostic.cgi via shell metacharacters in the ping_ipaddr parameter. | |||||
CVE-2009-5156 | 1 Veracomp | 2 Asmax Ar-804gu, Asmax Ar-804gu Firmware | 2019-06-12 | 10.0 HIGH | 9.8 CRITICAL |
An issue was discovered on ASMAX AR-804gu 66.34.1 devices. There is Command Injection via the cgi-bin/script query string. | |||||
CVE-2018-19451 | 2 Foxitsoftware, Microsoft | 2 Foxit Pdf Sdk Activex, Windows | 2019-06-10 | 6.8 MEDIUM | 7.8 HIGH |
A command injection can occur for specially crafted PDF files in Foxit Reader SDK (ActiveX) Professional 5.4.0.1031 when using the Open File action on a Field. An attacker can leverage this to gain remote code execution. | |||||
CVE-2018-7825 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2019-05-28 | 6.5 MEDIUM | 8.8 HIGH |
A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands. | |||||
CVE-2018-7826 | 1 Schneider-electric | 118 D6220, D6220 Firmware, D6220l and 115 more | 2019-05-28 | 6.5 MEDIUM | 8.8 HIGH |
A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to execute arbitrary commands. | |||||
CVE-2019-10854 | 1 Computrols | 1 Computrols Building Automation Software | 2019-05-24 | 9.0 HIGH | 8.8 HIGH |
Computrols CBAS 18.0.0 allows Authenticated Command Injection. | |||||
CVE-2019-6689 | 1 Dillonkane | 1 Tidal Workload Automation | 2019-05-02 | 7.2 HIGH | 7.8 HIGH |
An issue was discovered in Dillon Kane Tidal Workload Automation Agent 3.2.0.5 (formerly known as Cisco Workload Automation or CWA). The Enterprise Scheduler for AIX allows local users to gain privileges via Command Injection in crafted Tidal Job Buffers (TJB) parameters. NOTE: this vulnerability exists because the CVE-2014-3272 solution did not address AIX operating systems. | |||||
CVE-2019-11076 | 1 Cribl | 1 Cribl | 2019-04-29 | 7.5 HIGH | 9.8 CRITICAL |
Cribl UI 1.5.0 allows remote attackers to run arbitrary commands via an unauthenticated web request. | |||||
CVE-2019-11217 | 1 Bonobogitserver | 1 Bonobo Git Server | 2019-04-25 | 7.5 HIGH | 9.8 CRITICAL |
The GitController in Jakub Chodounsky Bonobo Git Server before 6.5.0 allows execution of arbitrary commands in the context of the web server via a crafted http request. | |||||
CVE-2016-1555 | 1 Netgear | 14 Wn604, Wn604 Firmware, Wn802tv2 and 11 more | 2019-04-16 | 10.0 HIGH | 9.8 CRITICAL |
(1) boardData102.php, (2) boardData103.php, (3) boardDataJP.php, (4) boardDataNA.php, and (5) boardDataWW.php in Netgear WN604 before 3.3.3 and WN802Tv2, WNAP210v2, WNAP320, WNDAP350, WNDAP360, and WNDAP660 before 3.5.5.0 allow remote attackers to execute arbitrary commands. | |||||
CVE-2019-9743 | 1 Phoenixcontact | 4 Rad-80211-xd, Rad-80211-xd\/hp-bus, Rad-80211-xd\/hp-bus Firmware and 1 more | 2019-04-05 | 9.0 HIGH | 8.8 HIGH |
An issue was discovered on PHOENIX CONTACT RAD-80211-XD and RAD-80211-XD/HP-BUS devices. Command injection can occur in the WebHMI component. | |||||
CVE-2015-4852 | 1 Oracle | 2 Virtual Desktop Infrastructure, Weblogic Server | 2019-03-28 | 7.5 HIGH | N/A |
The WLS Security component in Oracle WebLogic Server 10.3.6.0, 12.1.2.0, 12.1.3.0, and 12.2.1.0 allows remote attackers to execute arbitrary commands via a crafted serialized Java object in T3 protocol traffic to TCP port 7001, related to oracle_common/modules/com.bea.core.apache.commons.collections.jar. NOTE: the scope of this CVE is limited to the WebLogic Server product. | |||||
CVE-2019-9059 | 1 Cmsmadesimple | 1 Cms Made Simple | 2019-03-26 | 6.5 MEDIUM | 7.2 HIGH |
An issue was discovered in CMS Made Simple 2.2.8. It is possible, with an administrator account, to achieve command injection by modifying the path of the e-mail executable in Mail Settings, setting "sendmail" in the "Mailer" option, and launching the "Forgot your password" feature. | |||||
CVE-2019-7537 | 1 Pytroll | 1 Donfig | 2019-03-26 | 7.5 HIGH | 9.8 CRITICAL |
An issue was discovered in Donfig 0.3.0. There is a vulnerability in the collect_yaml method in config_obj.py. It can execute arbitrary Python commands, resulting in command execution. | |||||
CVE-2019-6275 | 1 Gl-inet | 2 Gl-ar300m-lite, Gl-ar300m-lite Firmware | 2019-03-25 | 6.5 MEDIUM | 8.8 HIGH |
Command injection vulnerability in firmware_cgi in GL.iNet GL-AR300M-Lite devices with firmware 2.27 allows remote attackers to execute arbitrary code. | |||||
CVE-2019-6272 | 1 Gl-inet | 2 Gl-ar300m-lite, Gl-ar300m-lite Firmware | 2019-03-25 | 6.5 MEDIUM | 8.8 HIGH |
Command injection vulnerability in login_cgi in GL.iNet GL-AR300M-Lite devices with firmware 2.27 allows remote attackers to execute arbitrary code. | |||||
CVE-2016-2002 | 1 Hp | 1 Vertica | 2019-02-20 | 10.0 HIGH | 9.8 CRITICAL |
The validateAdminConfig handler in the Analytics Management Console in HPE Vertica 7.0.x before 7.0.2.12, 7.1.x before 7.1.2-12, and 7.2.x before 7.2.2-1 allows remote attackers to execute arbitrary commands via the mcPort parameter, aka ZDI-CAN-3417. |