Total
351 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2019-19924 | 5 Apache, Netapp, Oracle and 2 more | 5 Bookkeeper, Cloud Backup, Mysql Workbench and 2 more | 2022-04-15 | 5.0 MEDIUM | 5.3 MEDIUM |
SQLite 3.30.1 mishandles certain parser-tree rewriting, related to expr.c, vdbeaux.c, and window.c. This is caused by incorrect sqlite3WindowRewrite() error handling. | |||||
CVE-2021-34593 | 1 Codesys | 2 Plcwinnt, Runtime Toolkit | 2022-04-12 | 5.0 MEDIUM | 7.5 HIGH |
In CODESYS V2 Runtime Toolkit 32 Bit full and PLCWinNT prior to versions V2.4.7.56 unauthenticated crafted invalid requests may result in several denial-of-service conditions. Running PLC programs may be stopped, memory may be leaked, or further communication clients may be blocked from accessing the PLC. | |||||
CVE-2020-27543 | 1 Restify-paginate Project | 1 Restify-paginate | 2022-04-08 | 5.0 MEDIUM | 7.5 HIGH |
The restify-paginate package 0.0.5 for Node.js allows remote attackers to cause a Denial-of-Service by omitting the HTTP Host header. A Restify-based web service would crash with an uncaught exception. | |||||
CVE-2022-23625 | 1 Wire | 2 Wire, Wire-ios-transport | 2022-03-18 | 4.0 MEDIUM | 6.5 MEDIUM |
Wire-ios is a messaging application using the wire protocol on apple's ios platform. In versions prior to 3.95 malformed resource identifiers may render the iOS Wire Client completely unusable by causing it to repeatedly crash on launch. These malformed resource identifiers can be generated and sent between Wire users. The root cause lies in [wireapp/wire-ios-transport](https://github.com/wireapp/wire-ios-transport), where code responsible for removing sensible tokens before logging may fail and lead to a crash (Swift exception) of the application. This causes undesirable behavior, however the (greater) Wire system is still functional. Users are advised to upgrade as soon as possible. There are no known workarounds for this issue. | |||||
CVE-2022-20057 | 2 Google, Mediatek | 23 Android, Mt6739, Mt6758 and 20 more | 2022-03-17 | 4.4 MEDIUM | 6.5 MEDIUM |
In btif, there is a possible memory corruption due to incorrect error handling. This could lead to local escalation of privilege with System execution privileges needed. User interaction is needed for exploitation. Patch ID: ALPS06271186; Issue ID: ALPS06271186. | |||||
CVE-2022-24613 | 1 Metadata-extractor Project | 1 Metadata-extractor | 2022-03-02 | 4.3 MEDIUM | 5.5 MEDIUM |
metadata-extractor up to 2.16.0 can throw various uncaught exceptions while parsing a specially crafted JPEG file, which could result in an application crash. This could be used to mount a denial of service attack against services that use metadata-extractor library. | |||||
CVE-2006-5170 | 3 Debian, Fedoraproject, Redhat | 8 Debian Linux, Fedora Core, Enterprise Linux and 5 more | 2022-02-25 | 7.5 HIGH | N/A |
pam_ldap in nss_ldap on Red Hat Enterprise Linux 4, Fedora Core 3 and earlier, and possibly other distributions does not return an error condition when an LDAP directory server responds with a PasswordPolicyResponse control response, which causes the pam_authenticate function to return a success code even if authentication has failed, as originally reported for xscreensaver. | |||||
CVE-2022-0016 | 3 Apple, Microsoft, Paloaltonetworks | 3 Macos, Windows, Globalprotect | 2022-02-17 | 6.9 MEDIUM | 7.8 HIGH |
An improper handling of exceptional conditions vulnerability exists within the Connect Before Logon feature of the Palo Alto Networks GlobalProtect app that enables a local attacker to escalate to SYSTEM or root privileges when authenticating with Connect Before Logon under certain circumstances. This issue impacts GlobalProtect app 5.2 versions earlier than GlobalProtect app 5.2.9 on Windows and MacOS. This issue does not affect the GlobalProtect app on other platforms. | |||||
CVE-2022-21218 | 1 Intel | 1 Trace Analyzer And Collector | 2022-02-15 | 2.1 LOW | 5.5 MEDIUM |
Uncaught exception in the Intel(R) Trace Analyzer and Collector before version 2021.5 may allow an authenticated user to potentially enable information disclosure via local access. | |||||
CVE-2022-20042 | 2 Google, Mediatek | 7 Android, Mt8167, Mt8175 and 4 more | 2022-02-11 | 2.1 LOW | 5.5 MEDIUM |
In Bluetooth, there is a possible information disclosure due to incorrect error handling. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS06108487; Issue ID: ALPS06108487. | |||||
CVE-2021-22285 | 1 Abb | 4 Pni800, Pni800 Firmware, Spiet800 and 1 more | 2022-02-09 | 5.0 MEDIUM | 7.5 HIGH |
Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive. | |||||
CVE-2019-6847 | 1 Schneider-electric | 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more | 2022-02-03 | 4.0 MEDIUM | 4.9 MEDIUM |
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the FTP service when upgrading the firmware with a version incompatible with the application in the controller using FTP protocol. | |||||
CVE-2019-6844 | 1 Schneider-electric | 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more | 2022-02-03 | 4.0 MEDIUM | 4.9 MEDIUM |
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service atack on the PLC when upgrading the controller with a firmware package containing an invalid web server image using FTP protocol. | |||||
CVE-2019-6841 | 1 Schneider-electric | 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more | 2022-02-03 | 4.0 MEDIUM | 4.9 MEDIUM |
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with no firmware image inside the package using FTP protocol. | |||||
CVE-2019-6842 | 1 Schneider-electric | 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more | 2022-02-03 | 4.0 MEDIUM | 4.9 MEDIUM |
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the firmware with a missing web server image inside the package using FTP protocol. | |||||
CVE-2019-6843 | 1 Schneider-electric | 8 Modicon 140cra, Modicon 140cra Firmware, Modicon Bmxcra and 5 more | 2022-02-03 | 4.0 MEDIUM | 4.9 MEDIUM |
A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol. | |||||
CVE-2019-6828 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus. | |||||
CVE-2019-6809 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller. | |||||
CVE-2019-6807 | 1 Schneider-electric | 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more | 2022-02-03 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. | |||||
CVE-2019-6829 | 1 Schneider-electric | 4 Modicon M340, Modicon M340 Firmware, Modicon M580 and 1 more | 2022-02-03 | 7.8 HIGH | 7.5 HIGH |
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus. |