Total
232 CVE
CVE | Vendors | Products | Updated | CVSS v2 | CVSS v3 |
---|---|---|---|---|---|
CVE-2020-12357 | 3 Intel, Netapp, Siemens | 568 Bios, Core I3-l13g4, Core I5-l16g7 and 565 more | 2022-04-22 | 4.6 MEDIUM | 6.7 MEDIUM |
Improper initialization in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. | |||||
CVE-2022-22186 | 1 Juniper | 2 Ex4650, Junos | 2022-04-21 | 6.4 MEDIUM | 6.5 MEDIUM |
Due to an Improper Initialization vulnerability in Juniper Networks Junos OS on EX4650 devices, packets received on the management interface (em0) but not destined to the device, may be improperly forwarded to an egress interface, instead of being discarded. Such traffic being sent by a client may appear genuine, but is non-standard in nature and should be considered as potentially malicious. This issue affects: Juniper Networks Junos OS on EX4650 Series: All versions prior to 19.1R3-S8; 19.2 versions prior to 19.2R3-S5; 19.3 versions prior to 19.3R3-S5; 19.4 versions prior to 19.4R3-S7; 20.1 versions prior to 20.1R3-S3; 20.2 versions prior to 20.2R3-S4; 20.3 versions prior to 20.3R3-S3; 20.4 versions prior to 20.4R3-S2; 21.1 versions prior to 21.1R3-S1; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2; 22.1 versions prior to 22.1R1. | |||||
CVE-2019-14271 | 3 Debian, Docker, Opensuse | 3 Debian Linux, Docker, Leap | 2022-04-18 | 7.5 HIGH | 9.8 CRITICAL |
In Docker 19.03.x before 19.03.1 linked against the GNU C Library (aka glibc), code injection can occur when the nsswitch facility dynamically loads a library inside a chroot that contains the contents of the container. | |||||
CVE-2021-44169 | 1 Fortinet | 1 Forticlient | 2022-04-14 | 4.6 MEDIUM | 8.8 HIGH |
A improper initialization in Fortinet FortiClient (Windows) version 6.0.10 and below, version 6.2.9 and below, version 6.4.7 and below, version 7.0.3 and below allows attacker to gain administrative privileges via placing a malicious executable inside the FortiClient installer's directory. | |||||
CVE-2020-11655 | 7 Canonical, Debian, Netapp and 4 more | 18 Ubuntu Linux, Debian Linux, Ontap Select Deploy Administration Utility and 15 more | 2022-04-08 | 5.0 MEDIUM | 7.5 HIGH |
SQLite through 3.31.1 allows attackers to cause a denial of service (segmentation fault) via a malformed window-function query because the AggInfo object's initialization is mishandled. | |||||
CVE-2019-15681 | 4 Canonical, Debian, Libvnc Project and 1 more | 15 Ubuntu Linux, Debian Linux, Libvncserver and 12 more | 2022-04-05 | 5.0 MEDIUM | 7.5 HIGH |
LibVNC commit before d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a contains a memory leak (CWE-655) in VNC server code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appear to be exploitable via network connectivity. These vulnerabilities have been fixed in commit d01e1bb4246323ba6fcee3b82ef1faa9b1dac82a. | |||||
CVE-2022-22657 | 1 Apple | 3 Garageband, Logic Pro X, Macos | 2022-03-25 | 6.8 MEDIUM | 7.8 HIGH |
A memory initialization issue was addressed with improved memory handling. This issue is fixed in Logic Pro 10.7.3, GarageBand 10.4.6, macOS Monterey 12.3. Opening a maliciously crafted file may lead to unexpected application termination or arbitrary code execution. | |||||
CVE-2012-0012 | 1 Microsoft | 4 Internet Explorer, Windows 7, Windows Server 2008 and 1 more | 2022-03-01 | 4.3 MEDIUM | N/A |
Microsoft Internet Explorer 9 does not properly handle the creation and initialization of string objects, which allows remote attackers to read data from arbitrary process-memory locations via a crafted web site, aka "Null Byte Information Disclosure Vulnerability." | |||||
CVE-2021-0119 | 2 Intel, Netapp | 1360 Atom C3308, Atom C3308 Firmware, Atom C3336 and 1357 more | 2022-02-16 | 4.6 MEDIUM | 6.2 MEDIUM |
Improper initialization in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via physical access. | |||||
CVE-2021-0125 | 2 Intel, Netapp | 1360 Atom C3308, Atom C3308 Firmware, Atom C3336 and 1357 more | 2022-02-16 | 4.6 MEDIUM | 6.6 MEDIUM |
Improper initialization in the firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via physical access. | |||||
CVE-2022-24316 | 1 Schneider-electric | 1 Interactive Graphical Scada System Data Server | 2022-02-15 | 5.0 MEDIUM | 7.5 HIGH |
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior) | |||||
CVE-2021-0145 | 2 Intel, Netapp | 121 Celeron 6305, Celeron 6305e, Celeron 6600he and 118 more | 2022-02-15 | 2.1 LOW | 5.5 MEDIUM |
Improper initialization of shared resources in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. | |||||
CVE-2021-46320 | 1 Openzeppelin | 1 Openzeppelin | 2022-02-09 | 5.0 MEDIUM | 7.5 HIGH |
In OpenZeppelin <=v4.4.0, initializer functions that are invoked separate from contract creation (the most prominent example being minimal proxies) may be reentered if they make an untrusted non-view external call. Once an initializer has finished running it can never be re-executed. However, an exception put in place to support multiple inheritance made reentrancy possible, breaking the expectation that there is a single execution. | |||||
CVE-2022-22169 | 1 Juniper | 2 Junos, Junos Os Evolved | 2022-02-01 | 4.3 MEDIUM | 5.9 MEDIUM |
An Improper Initialization vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an attacker who sends specific packets in certain orders and at specific timings to force OSPFv3 to unexpectedly enter graceful-restart (GR helper mode) even though there is not any Grace-LSA received in OSPFv3 causing a Denial of Service (DoS). Unexpectedly entering GR helper mode might cause the OSPFv3 neighbor adjacency formed on this interface to be stuck in the "INIT" state which can be observed by issuing the following command: user@device> show ospf3 neighbor ID Interface State xx.xx.xx.xx ae100.0 Init <<<<<<<<<< An indicator of compromise can be seen in log files when traceoptions for OSPFv3 are enabled before the issue occurs. These logfile messages are as follows: OSPF restart signaling: Received hello with LR bit set from nbr ip=xx::xx id=xx.xx.xx.xx. Set oob-resync capabilty 1. OSPF Restart Signaling: Start helper mode for nbr ip xx::xx id xx.xx.xx.xx OSPF restart signaling: abort helper mode for nbr ip=xx::xx id=xx.xx.xx.xx OSPF neighbor xx::xx (realm ipv6-unicast <interface.unit> area xx.xx.xx.xx) state changed from Full to Init due to 1WayRcvd (event reason: neighbor is in one-way mode) (nbr helped: 0) This issue affects: Juniper Networks Junos OS. 15.1 versions prior to 15.1R7-S11; 18.3 versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S7, 19.2R3-S4; 19.3 versions prior to 19.3R2-S7, 19.3R3-S4; 19.4 versions prior to 19.4R3-S6; 20.1 versions prior to 20.1R3-S1; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R2-S2, 20.4R3; 21.1 versions prior to 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. This issue does not affect any version of Juniper Networks Junos OS 12.3. This issue affects Juniper Networks Junos OS Evolved all versions prior to 21.2R2-EVO. | |||||
CVE-2022-22164 | 1 Juniper | 1 Junos Os Evolved | 2022-01-25 | 5.0 MEDIUM | 5.3 MEDIUM |
An Improper Initialization vulnerability in Juniper Networks Junos OS Evolved may cause a commit operation for disabling the telnet service to not take effect as expected, resulting in the telnet service staying enabled. When it is not intended to be operating on the device, an administrator can issue the following command to verify whether telnet is operating in the background: user@device > show system connections | grep :23 tcp 0 0 0.0.0.0:23 0.0.0.0:* LISTEN 20879/xinetd This issue affects: Juniper Networks Junos OS Evolved All versions prior to 20.4R2-S2-EVO; 21.1 version 21.1R1-EVO and later versions; 21.2 versions prior to 21.2R2-EVO. | |||||
CVE-2021-20613 | 1 Mitsubishielectric | 6 Fx3u-enet, Fx3u-enet-l, Fx3u-enet-l Firmware and 3 more | 2022-01-21 | 7.8 HIGH | 7.5 HIGH |
Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery. | |||||
CVE-2021-46283 | 1 Linux | 1 Linux Kernel | 2022-01-20 | 4.9 MEDIUM | 5.5 MEDIUM |
nf_tables_newset in net/netfilter/nf_tables_api.c in the Linux kernel before 5.12.13 allows local users to cause a denial of service (NULL pointer dereference and general protection fault) because of the missing initialization for nft_set_elem_expr_alloc. A local user can set a netfilter table expression in their own namespace. | |||||
CVE-2021-40025 | 1 Huawei | 1 Harmonyos | 2022-01-12 | 5.0 MEDIUM | 7.5 HIGH |
The eID module has a vulnerability that causes the memory to be used without being initialized,Successful exploitation of this vulnerability may affect data confidentiality. | |||||
CVE-2022-20015 | 2 Google, Mediatek | 25 Android, Mt6739, Mt6757 and 22 more | 2022-01-11 | 2.1 LOW | 4.4 MEDIUM |
In kd_camera_hw driver, there is a possible information disclosure due to uninitialized data. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS05862966; Issue ID: ALPS05862966. | |||||
CVE-2020-0561 | 4 Intel, Linux, Microsoft and 1 more | 5 Software Guard Extensions Sdk, Linux Kernel, Windows and 2 more | 2022-01-01 | 4.6 MEDIUM | 7.8 HIGH |
Improper initialization in the Intel(R) SGX SDK before v2.6.100.1 may allow an authenticated user to potentially enable escalation of privilege via local access. |