A vulnerability has been identified in SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L, SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/2 HF (incl. SIPLUS variants), SIMATIC ET200SP IM155-6 PN/3 HF (incl. SIPLUS variants), SIMATIC PN/MF Coupler, SIMATIC PN/PN Coupler, SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010, SIMATIC WinAC RTX F 2010, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. SIPLUS variants), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. SIPLUS variants), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP. The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
References
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-400_pn\/dp_v7_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-400_pn\/dp_v7:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*

Configuration 12 (hide)

cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*

Information

Published : 2022-04-12 02:15

Updated : 2023-02-14 03:15


NVD link : CVE-2022-25622

Mitre link : CVE-2022-25622


JSON object : View

CWE
CWE-400

Uncontrolled Resource Consumption

Advertisement

dedicated server usa

Products Affected

siemens

  • simatic_cfu_diq_firmware
  • simatic_cfu_pa_firmware
  • simatic_s7-400_pn\/dp_v7_firmware
  • simatic_tdc_cp51m1_firmware
  • simatic_s7-400_pn\/dp_v7
  • simatic_s7-300_cpu
  • simatic_s7-410_v10_firmware
  • simatic_tdc_cpu555
  • simatic_s7-300_cpu_firmware
  • simatic_cfu_pa
  • simatic_tdc_cp51m1
  • simatic_winac_rtx
  • simatic_winac_rtx_firmware
  • simit_simulation_platform
  • simatic_tdc_cpu555_firmware
  • simatic_cfu_diq
  • simatic_s7-400h_v6_firmware
  • simatic_s7-400h_v6
  • simatic_s7-1500_cpu_firmware
  • simatic_s7-1500_cpu
  • simatic_s7-410_v8
  • simatic_s7-410_v8_firmware
  • simatic_s7-410_v10