AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
References
Link Resource
https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03 Patch Third Party Advisory US Government Resource
https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02 Patch Third Party Advisory US Government Resource
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:automationdirect:d0-06dd1_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06dd1:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:automationdirect:d0-06dd2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06dd2:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:automationdirect:d0-06dr_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06dr:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:automationdirect:d0-06da_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06da:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:automationdirect:d0-06ar_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06ar:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:automationdirect:d0-06aa_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06aa:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:automationdirect:d0-06dd1-d_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06dd1-d:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:automationdirect:d0-06dd2-d_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06dd2-d:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:automationdirect:d0-06dr-d_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:automationdirect:d0-06dr-d:-:*:*:*:*:*:*:*

Information

Published : 2022-08-31 09:15

Updated : 2022-09-06 16:50


NVD link : CVE-2022-2003

Mitre link : CVE-2022-2003


JSON object : View

CWE
CWE-319

Cleartext Transmission of Sensitive Information

Advertisement

dedicated server usa

Products Affected

automationdirect

  • d0-06da
  • d0-06dd2-d
  • d0-06aa
  • d0-06aa_firmware
  • d0-06dr-d
  • d0-06dr-d_firmware
  • d0-06dd1
  • d0-06ar_firmware
  • d0-06dd2_firmware
  • d0-06dd2
  • d0-06dd1-d_firmware
  • d0-06dd2-d_firmware
  • d0-06dd1-d
  • d0-06ar
  • d0-06dd1_firmware
  • d0-06da_firmware
  • d0-06dr
  • d0-06dr_firmware