CVE-2022-1343

The function `OCSP_basic_verify` verifies the signer certificate on an OCSP response. In the case where the (non-default) flag OCSP_NOCHECKS is used then the response will be positive (meaning a successful verification) even in the case where the response signing certificate fails to verify. It is anticipated that most users of `OCSP_basic_verify` will not use the OCSP_NOCHECKS flag. In this case the `OCSP_basic_verify` function will return a negative value (indicating a fatal error) in the case of a certificate verification failure. The normal expected return value in this case would be 0. This issue also impacts the command line OpenSSL "ocsp" application. When verifying an ocsp response with the "-no_cert_checks" option the command line application will report that the verification is successful even though it has in fact failed. In this case the incorrect successful response will also be accompanied by error messages showing the failure and contradicting the apparently successful result. Fixed in OpenSSL 3.0.3 (Affected 3.0.0,3.0.1,3.0.2).
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*

Configuration 2 (hide)

OR cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:clustered_data_ontap:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:smi-s_provider:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:clustered_data_ontap_antivirus_connector:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:solidfire_\&_hci_management_node:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:solidfire\,_enterprise_sds_\&_hci_storage_node:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vsphere:*:*
cpe:2.3:a:netapp:snapmanager:-:*:*:*:*:hyper-v:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:netapp:a250_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:a250:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:netapp:a700s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:a700s:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:netapp:aff_500f_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:aff_500f:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:netapp:aff_8300_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:aff_8300:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:netapp:aff_8700_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:aff_8700:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:netapp:aff_a400_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:aff_a400:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:netapp:fabric-attached_storage_a400_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:fabric-attached_storage_a400:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:netapp:fas_500f_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:fas_500f:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:netapp:fas_8300_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:fas_8300:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:netapp:fas_8700_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:fas_8700:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:netapp:h300e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h300e:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:netapp:h500e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h500e:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*

Configuration 18 (hide)

AND
cpe:2.3:o:netapp:h700e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h700e:-:*:*:*:*:*:*:*

Configuration 19 (hide)

AND
cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*

Information

Published : 2022-05-03 09:15

Updated : 2023-02-14 04:15


NVD link : CVE-2022-1343

Mitre link : CVE-2022-1343


JSON object : View

CWE
CWE-295

Improper Certificate Validation

Advertisement

dedicated server usa

Products Affected

netapp

  • fas_8700
  • h500s
  • solidfire_\&_hci_management_node
  • active_iq_unified_manager
  • aff_a400_firmware
  • aff_500f
  • h410s_firmware
  • a250_firmware
  • aff_8700_firmware
  • aff_8300_firmware
  • aff_8700
  • h300e_firmware
  • snapmanager
  • clustered_data_ontap_antivirus_connector
  • a250
  • fabric-attached_storage_a400_firmware
  • clustered_data_ontap
  • fas_500f
  • h700e_firmware
  • fas_8300
  • aff_a400
  • h700s
  • solidfire\,_enterprise_sds_\&_hci_storage_node
  • fabric-attached_storage_a400
  • fas_500f_firmware
  • h300s_firmware
  • h410s
  • h500s_firmware
  • h300e
  • fas_8700_firmware
  • a700s
  • a700s_firmware
  • santricity_smi-s_provider
  • h300s
  • h700e
  • aff_500f_firmware
  • fas_8300_firmware
  • h500e
  • smi-s_provider
  • h500e_firmware
  • aff_8300
  • h700s_firmware

openssl

  • openssl