{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://www.insyde.com/security-pledge", "name": "https://www.insyde.com/security-pledge", "tags": ["Vendor Advisory"], "refsource": "MISC"}, {"url": "https://www.insyde.com/security-pledge/SA-2022012", "name": "https://www.insyde.com/security-pledge/SA-2022012", "tags": ["Vendor Advisory"], "refsource": "MISC"}, {"url": "https://security.netapp.com/advisory/ntap-20220216-0007/", "name": "https://security.netapp.com/advisory/ntap-20220216-0007/", "tags": ["Third Party Advisory"], "refsource": "CONFIRM"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf", "tags": ["Third Party Advisory"], "refsource": "CONFIRM"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-787"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2021-42554", "ASSIGNER": "cve@mitre.org"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 7.2, "accessVector": "LOCAL", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "authentication": "NONE", "integrityImpact": "COMPLETE", "accessComplexity": "LOW", "availabilityImpact": "COMPLETE", "confidentialityImpact": "COMPLETE"}, "severity": "HIGH", "acInsufInfo": false, "impactScore": 10.0, "obtainAllPrivilege": false, "exploitabilityScore": 3.9, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}, "baseMetricV3": {"cvssV3": {"scope": "CHANGED", "version": "3.1", "baseScore": 8.2, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "HIGH", "confidentialityImpact": "HIGH"}, "impactScore": 6.0, "exploitabilityScore": 1.5}}, "publishedDate": "2022-02-03T02:15Z", "configurations": {"nodes": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.08.42", "versionStartIncluding": "5.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.16.42", "versionStartIncluding": "5.1"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.26.42", "versionStartIncluding": "5.2"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.35.42", "versionStartIncluding": "5.3"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.42.51", "versionStartIncluding": "5.4"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:insyde:insydeh2o:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.50.51", "versionStartIncluding": "5.5"}]}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_itp1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2022-03-08T20:18Z"}