Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf", "name": "N/A", "tags": ["Vendor Advisory"], "refsource": "CONFIRM"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf", "name": "N/A", "tags": ["Vendor Advisory"], "refsource": "CONFIRM"}, {"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-867/", "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-867/", "tags": ["Third Party Advisory", "VDB Entry"], "refsource": "MISC"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13427)"}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-787"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2021-34329", "ASSIGNER": "productcert@siemens.com"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "severity": "MEDIUM", "acInsufInfo": false, "impactScore": 6.4, "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}, "baseMetricV3": {"cvssV3": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.8, "attackVector": "LOCAL", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.8}}, "publishedDate": "2021-07-13T11:15Z", "configurations": {"nodes": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "se2021"}, {"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "13.2.0"}, {"cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "13.2.0"}, {"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2022-10-07T20:47Z"}