CVE-2021-31892

A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:siemens:sinumerik_analyse_mycondition_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_analyse_mycondition:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:sinumerik_analyze_myperformance_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_analyze_myperformance:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
OR cpe:2.3:o:siemens:sinumerik_integrate_client_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_integrate_client_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_integrate_client_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_integrate_client:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
OR cpe:2.3:o:siemens:sinumerik_integrate_for_production_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_integrate_for_production_firmware:5.1:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_integrate_for_production:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:sinumerik_manage_mymachines_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_manage_mymachines:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:sinumerik_manage_myprograms_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_manage_myprograms:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:sinumerik_manage_myresources_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_manage_myresources:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:sinumerik_manage_mytools_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_manage_mytools:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
OR cpe:2.3:o:siemens:sinumerik_operate_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:-:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp1:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp2:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp3:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp4:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp5:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp6:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.8:sp7:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:-:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_1:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_1:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_2:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_3:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:hotfix_4:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_2:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_3:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_4:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_5:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.94:-:*:*:*:*:*:*
cpe:2.3:o:siemens:sinumerik_operate_firmware:4.93:hotfix_6:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_operate:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:siemens:sinumerik_optimize_myprogramming_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:siemens:sinumerik_optimize_myprogramming:-:*:*:*:*:*:*:*

Information

Published : 2021-07-13 04:15

Updated : 2021-08-09 09:26


NVD link : CVE-2021-31892

Mitre link : CVE-2021-31892


JSON object : View

CWE
CWE-295

Improper Certificate Validation

Advertisement

dedicated server usa

Products Affected

siemens

  • sinumerik_analyse_mycondition
  • sinumerik_integrate_for_production_firmware
  • sinumerik_integrate_for_production
  • sinumerik_manage_mymachines
  • sinumerik_manage_myprograms
  • sinumerik_optimize_myprogramming
  • sinumerik_manage_myprograms_firmware
  • sinumerik_manage_mymachines_firmware
  • sinumerik_operate
  • sinumerik_manage_myresources
  • sinumerik_analyze_myperformance
  • sinumerik_analyze_myperformance_firmware
  • sinumerik_operate_firmware
  • sinumerik_optimize_myprogramming_firmware
  • sinumerik_manage_mytools
  • sinumerik_manage_mytools_firmware
  • sinumerik_analyse_mycondition_firmware
  • sinumerik_integrate_client
  • sinumerik_integrate_client_firmware
  • sinumerik_manage_myresources_firmware