A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.1), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). TFTP server application allows for reading the contents of the TFTP memory buffer via sending malformed TFTP commands. (FSMD-2021-0009)
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | Vendor Advisory |
https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf |
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
AND |
|
Configuration 3 (hide)
AND |
|
Configuration 4 (hide)
AND |
|
Configuration 5 (hide)
AND |
|
Configuration 6 (hide)
AND |
|
Configuration 7 (hide)
AND |
|
Information
Published : 2021-11-09 04:15
Updated : 2022-05-20 06:15
NVD link : CVE-2021-31885
Mitre link : CVE-2021-31885
JSON object : View
CWE
CWE-805
Buffer Access with Incorrect Length Value
Products Affected
siemens
- nucleus_readystart_v3
- talon_tc_compact
- apogee_modular_building_controller_firmware
- nucleus_net
- apogee_pxc_compact
- apogee_modular_building_controller
- apogee_modular_equiment_controller_firmware
- apogee_pxc_compact_firmware
- nucleus_source_code
- talon_tc_modular
- apogee_modular_equiment_controller
- nucleus_readystart_v4
- talon_tc_compact_firmware
- apogee_pxc_modular
- talon_tc_modular_firmware
- capital_vstar
- apogee_pxc_modular_firmware