CVE-2021-31345

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

OR cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*
cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*

Information

Published : 2021-11-09 04:15

Updated : 2022-05-20 06:15


NVD link : CVE-2021-31345

Mitre link : CVE-2021-31345


JSON object : View

CWE
CWE-1284

Improper Validation of Specified Quantity in Input

Advertisement

dedicated server usa

Products Affected

siemens

  • nucleus_readystart_v3
  • talon_tc_compact
  • apogee_modular_building_controller_firmware
  • nucleus_net
  • apogee_pxc_compact
  • apogee_modular_building_controller
  • apogee_modular_equiment_controller_firmware
  • apogee_pxc_compact_firmware
  • nucleus_source_code
  • talon_tc_modular
  • apogee_modular_equiment_controller
  • talon_tc_compact_firmware
  • apogee_pxc_modular
  • talon_tc_modular_firmware
  • capital_vstar
  • apogee_pxc_modular_firmware