A vulnerability has been identified in Capital VSTAR (Versions including affected IPv6 stack), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.
                
            References
                    | Link | Resource | 
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf | Vendor Advisory | 
| https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05 | Third Party Advisory US Government Resource | 
Configurations
                    Configuration 1 (hide)
                                
                                
  | 
                        
Configuration 2 (hide)
                                
                                
  | 
                        
Information
                Published : 2021-04-22 14:15
Updated : 2021-12-10 11:55
NVD link : CVE-2021-25663
Mitre link : CVE-2021-25663
JSON object : View
CWE
                
                    
                        
                        CWE-835
                        
            Loop with Unreachable Exit Condition ('Infinite Loop')
Products Affected
                siemens
- nucleus_readystart
 - nucleus_source_code
 - capital_vstar
 - nucleus_net
 