A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
References
Link | Resource |
---|---|
https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-285-03 | Patch Vendor Advisory |
Configurations
Configuration 1 (hide)
|
Information
Published : 2022-02-11 10:15
Updated : 2022-02-18 07:16
NVD link : CVE-2021-22804
Mitre link : CVE-2021-22804
JSON object : View
CWE
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Products Affected
schneider-electric
- interactive_graphical_scada_system_data_collector