Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/", "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-04/", "tags": ["Vendor Advisory"], "refsource": "MISC"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "A CWE-79: Improper Neutralization of Input During Web Page Generation vulnerability exists in EcoStruxure\u00aa and SmartStruxure\u00aa Power Monitoring and SCADA Software (see security notification for version information) that could allow an attacker to perform actions on behalf of the authorized user when accessing an affected webpage."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-79"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2020-7546", "ASSIGNER": "cybersecurity@schneider-electric.com"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 3.5, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "authentication": "SINGLE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "NONE", "confidentialityImpact": "NONE"}, "severity": "LOW", "acInsufInfo": false, "impactScore": 2.9, "obtainAllPrivilege": false, "exploitabilityScore": 6.8, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}, "baseMetricV3": {"cvssV3": {"scope": "CHANGED", "version": "3.1", "baseScore": 5.4, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "integrityImpact": "LOW", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "LOW", "confidentialityImpact": "LOW"}, "impactScore": 2.7, "exploitabilityScore": 2.3}}, "publishedDate": "2020-12-01T15:15Z", "configurations": {"nodes": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_energy_expert:2.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:7.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:8.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:9.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:schneider-electric:power_manager:1.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:schneider-electric:power_manager:1.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:schneider-electric:power_manager:1.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:schneider-electric:powerscada_expert_with_advanced_reporting_and_dashboards:8.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:schneider-electric:powerscada_operation_with_advanced_reporting_and_dashboards:9.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2020-12-04T20:43Z"}