Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1057", "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2020-1057", "tags": ["Third Party Advisory"], "refsource": "MISC"}, {"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-047-02", "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-047-02", "tags": ["Third Party Advisory", "US Government Resource"], "refsource": "MISC"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "An exploitable denial-of-service vulnerability exists in the IPv4 functionality of Allen-Bradley MicroLogix 1100 Programmable Logic Controller Systems Series B FRN 16.000, Series B FRN 15.002, Series B FRN 15.000, Series B FRN 14.000, Series B FRN 13.000, Series B FRN 12.000, Series B FRN 11.000 and Series B FRN 10.000. A specially crafted packet can cause a major error, resulting in a denial of service. An attacker can send a malicious packet to trigger this vulnerability."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "NVD-CWE-noinfo"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2020-6111", "ASSIGNER": "talos-cna@cisco.com"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "LOW", "availabilityImpact": "PARTIAL", "confidentialityImpact": "NONE"}, "severity": "MEDIUM", "acInsufInfo": false, "impactScore": 2.9, "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}, "baseMetricV3": {"cvssV3": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 3.6, "exploitabilityScore": 3.9}}, "publishedDate": "2020-12-03T13:15Z", "configurations": {"nodes": [{"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_b_firmware:10.000:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_b_firmware:11.000:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_b_firmware:12.000:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_b_firmware:13.000:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_b_firmware:14.000:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_b_firmware:15.000:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_b_firmware:15.002:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:o:rockwellautomation:micrologix_1100_b_firmware:16.000:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:rockwellautomation:micrologix_1100:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2022-05-12T17:27Z"}