Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf", "tags": ["Vendor Advisory"], "refsource": "MISC"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf", "tags": ["Vendor Advisory"], "refsource": "CONFIRM"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf", "tags": [], "refsource": "CONFIRM"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions < V3.5.5), APOGEE PXC Series (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus ReadyStart V3 (All versions < V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Series (BACnet) (All versions < V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-342"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2020-28388", "ASSIGNER": "productcert@siemens.com"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 5.0, "accessVector": "NETWORK", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "LOW", "availabilityImpact": "NONE", "confidentialityImpact": "NONE"}, "severity": "MEDIUM", "acInsufInfo": false, "impactScore": 2.9, "obtainAllPrivilege": false, "exploitabilityScore": 10.0, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}, "baseMetricV3": {"cvssV3": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 5.3, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "integrityImpact": "LOW", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "NONE", "privilegesRequired": "NONE", "confidentialityImpact": "NONE"}, "impactScore": 1.4, "exploitabilityScore": 3.9}}, "publishedDate": "2021-02-09T18:15Z", "configurations": {"nodes": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "5.2"}, {"cpe23Uri": "cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:siemens:pluscontrol_1st_gen:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "2012.12"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:powerpc_project:powerpc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}, {"cpe23Uri": "cpe:2.3:h:arm:arm:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}, {"cpe23Uri": "cpe:2.3:h:mips:mips:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2022-12-13T16:15Z"}