Barco wePresent WiPG-1600W devices have Improper Access Control. Affected Version(s): 2.5.1.8. The Barco wePresent WiPG-1600W device has an SSH daemon included in the firmware image. By default, the SSH daemon is disabled and does not start at system boot. The system initialization scripts read a device configuration file variable to see if the SSH daemon should be started. The web interface does not provide a visible capability to alter this configuration file variable. However, a malicious actor can include this variable in a POST such that the SSH daemon will be started when the device boots.
References
Link | Resource |
---|---|
http://packetstormsecurity.com/files/160162/Barco-wePresent-Undocumented-SSH-Interface.html | Third Party Advisory VDB Entry |
https://korelogic.com/Resources/Advisories/KL-001-2020-007.txt | Third Party Advisory |
Configurations
Configuration 1 (hide)
AND |
|
Information
Published : 2020-11-24 10:15
Updated : 2022-07-12 10:42
NVD link : CVE-2020-28331
Mitre link : CVE-2020-28331
JSON object : View
CWE
Products Affected
barco
- wepresent_wipg-1600w
- wepresent_wipg-1600w_firmware