Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf", "tags": ["Patch", "Vendor Advisory"], "refsource": "MISC"}, {"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf", "tags": ["Patch", "Vendor Advisory"], "refsource": "MISC"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "A vulnerability has been identified in Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-788"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2020-27738", "ASSIGNER": "productcert@siemens.com"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 5.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P", "authentication": "NONE", "integrityImpact": "NONE", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "severity": "MEDIUM", "acInsufInfo": false, "impactScore": 4.9, "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}, "baseMetricV3": {"cvssV3": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.4, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H", "integrityImpact": "NONE", "userInteraction": "NONE", "attackComplexity": "HIGH", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.2, "exploitabilityScore": 2.2}}, "publishedDate": "2021-04-22T21:15Z", "configurations": {"nodes": [{"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simotics_connect_400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "0.5.0.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simotics_connect_400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}, {"cpe23Uri": "cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "2017.02.3"}, {"cpe23Uri": "cpe:2.3:a:siemens:nucleus_readystart_v4:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "4.1.0"}, {"cpe23Uri": "cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2022-04-22T19:44Z"}