CVE-2020-25176

Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

AND
cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:easergy_t300:-:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
cpe:2.3:o:schneider-electric:easergy_c5_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:easergy_c5:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:o:schneider-electric:micom_c264_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:micom_c264:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
OR cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.1:*:*:*:*:windows:*:*
cpe:2.3:o:schneider-electric:pacis_gtw_firmware:5.2:*:*:*:*:windows:*:*
cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.1:*:*:*:*:windows:*:*
cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:linux:*:*
cpe:2.3:o:schneider-electric:pacis_gtw_firmware:6.3:*:*:*:*:windows:*:*
cpe:2.3:h:schneider-electric:pacis_gtw:-:*:*:*:*:*:*:*

Configuration 5 (hide)

AND
cpe:2.3:o:schneider-electric:saitel_dp_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:saitel_dp:-:*:*:*:*:*:*:*

Configuration 6 (hide)

AND
OR cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:linux:*:*
cpe:2.3:o:schneider-electric:epas_gtw_firmware:6.4:*:*:*:*:windows:*:*
cpe:2.3:h:schneider-electric:epas_gtw:-:*:*:*:*:*:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:schneider-electric:saitel_dr_firmware:*:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:saitel_dr:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:schneider-electric:scd2200_firmware:*:*:*:*:*:*:*:*
OR cpe:2.3:h:schneider-electric:cp-3:-:*:*:*:*:*:*:*
cpe:2.3:h:schneider-electric:mc-31:-:*:*:*:*:*:*:*

Configuration 9 (hide)

OR cpe:2.3:a:rockwellautomation:aadvance_controller:*:*:*:*:*:*:*:*
cpe:2.3:a:rockwellautomation:isagraf_free_runtime:*:*:*:*:*:isagraf6_workbench:*:*
cpe:2.3:a:rockwellautomation:isagraf_runtime:*:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:rockwellautomation:micro810_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micro810:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:rockwellautomation:micro820_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micro820:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:rockwellautomation:micro830_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micro830:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:rockwellautomation:micro850_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micro850:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:rockwellautomation:micro870_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:rockwellautomation:micro870:-:*:*:*:*:*:*:*

Configuration 15 (hide)

cpe:2.3:o:xylem:multismart_firmware:*:*:*:*:*:*:*:*

Information

Published : 2022-03-18 11:15

Updated : 2022-04-04 13:56


NVD link : CVE-2020-25176

Mitre link : CVE-2020-25176


JSON object : View

CWE
CWE-22

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')

Advertisement

dedicated server usa

Products Affected

schneider-electric

  • micom_c264_firmware
  • pacis_gtw_firmware
  • epas_gtw
  • easergy_t300_firmware
  • easergy_c5_firmware
  • easergy_c5
  • pacis_gtw
  • micom_c264
  • saitel_dr_firmware
  • saitel_dp
  • epas_gtw_firmware
  • mc-31
  • cp-3
  • easergy_t300
  • saitel_dp_firmware
  • saitel_dr
  • scd2200_firmware

rockwellautomation

  • micro870
  • isagraf_free_runtime
  • aadvance_controller
  • micro850
  • micro810_firmware
  • micro870_firmware
  • micro830_firmware
  • isagraf_runtime
  • micro810
  • micro820_firmware
  • micro820
  • micro830
  • micro850_firmware

xylem

  • multismart_firmware