CVE-2020-12888

The VFIO PCI driver in the Linux kernel through 5.6.13 mishandles attempts to access disabled memory space.
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*

Configuration 2 (hide)

OR cpe:2.3:o:fedoraproject:fedora:31:*:*:*:*:*:*:*
cpe:2.3:o:fedoraproject:fedora:32:*:*:*:*:*:*:*

Configuration 3 (hide)

OR cpe:2.3:o:opensuse:leap:15.1:*:*:*:*:*:*:*
cpe:2.3:o:opensuse:leap:15.2:*:*:*:*:*:*:*

Configuration 4 (hide)

cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*

Configuration 5 (hide)

OR cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*
cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:esm:*:*:*
cpe:2.3:o:canonical:ubuntu_linux:20.04:*:*:*:lts:*:*:*
cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:esm:*:*:*

Configuration 6 (hide)

OR cpe:2.3:a:netapp:cloud_backup:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:element_software:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:steelstore_cloud_integrated_storage:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:solidfire:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:hci_management_node:-:*:*:*:*:*:*:*
cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*

Configuration 7 (hide)

AND
cpe:2.3:o:netapp:solidfire_baseboard_management_controller_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:solidfire_baseboard_management_controller:-:*:*:*:*:*:*:*

Configuration 8 (hide)

AND
cpe:2.3:o:netapp:bootstrap_os:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:hci_compute_node:-:*:*:*:*:*:*:*

Configuration 9 (hide)

AND
cpe:2.3:o:netapp:a700s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:a700s:-:*:*:*:*:*:*:*

Configuration 10 (hide)

AND
cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*

Configuration 11 (hide)

AND
cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*

Configuration 12 (hide)

AND
cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*

Configuration 13 (hide)

AND
cpe:2.3:o:netapp:h300e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h300e:-:*:*:*:*:*:*:*

Configuration 14 (hide)

AND
cpe:2.3:o:netapp:h500e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h500e:-:*:*:*:*:*:*:*

Configuration 15 (hide)

AND
cpe:2.3:o:netapp:h700e_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h700e:-:*:*:*:*:*:*:*

Configuration 16 (hide)

AND
cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*

Configuration 17 (hide)

AND
cpe:2.3:o:netapp:h410c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h410c:-:*:*:*:*:*:*:*

Configuration 18 (hide)

AND
cpe:2.3:o:netapp:h610c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h610c:-:*:*:*:*:*:*:*

Configuration 19 (hide)

AND
cpe:2.3:o:netapp:h610s_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h610s:-:*:*:*:*:*:*:*

Configuration 20 (hide)

AND
cpe:2.3:o:netapp:h615c_firmware:-:*:*:*:*:*:*:*
cpe:2.3:h:netapp:h615c:-:*:*:*:*:*:*:*

Information

Published : 2020-05-15 11:15

Updated : 2022-11-14 11:44


NVD link : CVE-2020-12888

Mitre link : CVE-2020-12888


JSON object : View

CWE
CWE-755

Improper Handling of Exceptional Conditions

Advertisement

dedicated server usa

Products Affected

netapp

  • cloud_backup
  • h410c_firmware
  • h500s
  • h610s_firmware
  • active_iq_unified_manager
  • steelstore_cloud_integrated_storage
  • h610c
  • h610s
  • h410s_firmware
  • h300e_firmware
  • h615c
  • h610c_firmware
  • h700e_firmware
  • h615c_firmware
  • element_software
  • solidfire
  • h700s
  • h410c
  • h500s_firmware
  • h300s_firmware
  • solidfire_baseboard_management_controller
  • h410s
  • solidfire_baseboard_management_controller_firmware
  • hci_compute_node
  • h300e
  • a700s
  • a700s_firmware
  • h300s
  • h700e
  • hci_management_node
  • h500e
  • h500e_firmware
  • bootstrap_os
  • h700s_firmware

canonical

  • ubuntu_linux

linux

  • linux_kernel

fedoraproject

  • fedora

debian

  • debian_linux

opensuse

  • leap