FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.
                
            References
                    | Link | Resource | 
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-20-163-02 | Third Party Advisory US Government Resource | 
Configurations
                    Configuration 1 (hide)
| 
 | 
Information
                Published : 2020-06-15 13:15
Updated : 2020-06-24 08:39
NVD link : CVE-2020-12005
Mitre link : CVE-2020-12005
JSON object : View
CWE
                
                    
                        
                        CWE-434
                        
            Unrestricted Upload of File with Dangerous Type
Products Affected
                rockwellautomation
- factorytalk_linx
- rslinx_classic


