Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
References
Link | Resource |
---|---|
https://www.us-cert.gov/ics/advisories/icsa-20-105-03 | Third Party Advisory US Government Resource |
https://www.zerodayinitiative.com/advisories/ZDI-20-547/ | Third Party Advisory VDB Entry |
Configurations
Information
Published : 2020-04-15 12:15
Updated : 2020-04-22 10:22
NVD link : CVE-2020-10615
Mitre link : CVE-2020-10615
JSON object : View
CWE
CWE-787
Out-of-bounds Write
Products Affected
trianglemicroworks
- scada_data_gateway