CVE-2019-1864

A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) Software could allow an authenticated, remote attacker to inject arbitrary commands that are executed with root privileges on an affected device. The vulnerability is due to insufficient validation of command input by the affected software. An attacker could exploit this vulnerability by sending malicious commands to the web-based management interface of the affected software. A successful exploit could allow the attacker, with read-only privileges, to inject and execute arbitrary, system-level commands with root privileges on an affected device.
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

cpe:2.3:a:cisco:unified_computing_system:4.0\(1c\)hs3:*:*:*:*:*:*:*

Configuration 2 (hide)

AND
OR cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*
cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*
cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*
cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*
OR cpe:2.3:h:cisco:encs_5400:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e140s-m2:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e160s-m3:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_s3260:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e168d-m2:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e180d-m3:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_c125_m5:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_c4200:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:encs_5100:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e1120d-m3:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e160d-m2:-:*:*:*:*:*:*:*

Configuration 3 (hide)

AND
cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*
OR cpe:2.3:h:cisco:ucs-e160d-m2:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e168d-m2:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e180d-m3:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_c125_m5:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_c4200:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_s3260:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:encs_5100:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:encs_5400:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e1120d-m3:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e140s-m2:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e160s-m3:-:*:*:*:*:*:*:*

Configuration 4 (hide)

AND
cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*
OR cpe:2.3:h:cisco:encs_5100:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e160s-m3:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e180d-m3:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_c4200:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_s3260:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:encs_5400:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e1120d-m3:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e140s-m2:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e160d-m2:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs-e168d-m2:-:*:*:*:*:*:*:*
cpe:2.3:h:cisco:ucs_c125_m5:-:*:*:*:*:*:*:*

Information

Published : 2019-08-21 12:15

Updated : 2019-10-09 16:48


NVD link : CVE-2019-1864

Mitre link : CVE-2019-1864


JSON object : View

CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Advertisement

dedicated server usa

Products Affected

cisco

  • integrated_management_controller_supervisor
  • ucs_s3260
  • ucs_c4200
  • ucs-e1120d-m3
  • unified_computing_system
  • ucs-e160d-m2
  • ucs-e160s-m3
  • ucs_c125_m5
  • encs_5400
  • ucs-e168d-m2
  • ucs-e180d-m3
  • encs_5100
  • ucs-e140s-m2