A vulnerability has been identified in SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf | Mitigation Vendor Advisory |
Configurations
Configuration 1 (hide)
|
Information
Published : 2019-12-12 11:15
Updated : 2022-03-04 12:51
NVD link : CVE-2019-18332
Mitre link : CVE-2019-18332
JSON object : View
CWE
CWE-287
Improper Authentication
Products Affected
siemens
- sppa-t3000_application_server