ExaGrid appliances with firmware version v4.8.1.1044.P50 have a /monitor/data/Upgrade/ directory traversal vulnerability, which allows remote attackers to view and retrieve verbose logging information. Files within this directory were observed to contain sensitive run-time information, including Base64 encoded 'support' credentials, leading to administrative access of the device.
References
Link | Resource |
---|---|
https://www.inquisitllc.com/exagrid-directory-traversal-vulnerability-to-support-credential-extraction/ | Exploit Third Party Advisory |
https://exagrid.com/exagrid-products/resources/ | Vendor Advisory |
Configurations
Configuration 1 (hide)
AND |
|
Information
Published : 2019-06-03 12:29
Updated : 2019-06-04 12:08
NVD link : CVE-2019-12310
Mitre link : CVE-2019-12310
JSON object : View
CWE
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Products Affected
exagrid
- backup_appliance
- backup_appliance_firmware