A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
Link | Resource |
---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf | Vendor Advisory |
http://www.securityfocus.com/bid/108382 | Third Party Advisory VDB Entry |
https://seclists.org/bugtraq/2019/May/72 | Mailing List Third Party Advisory |
http://packetstormsecurity.com/files/153122/Siemens-LOGO-8-Hard-Coded-Cryptographic-Key.html | Third Party Advisory VDB Entry |
http://seclists.org/fulldisclosure/2019/May/44 | Mailing List Third Party Advisory |
Configurations
Configuration 1 (hide)
AND |
|
Information
Published : 2019-05-14 13:29
Updated : 2022-01-04 10:10
NVD link : CVE-2019-10920
Mitre link : CVE-2019-10920
JSON object : View
CWE
CWE-321
Use of Hard-coded Cryptographic Key
Products Affected
siemens
- logo\!8_bm
- logo\!8_bm_firmware