The time-based one-time-password (TOTP) function in the application logic of the Green Electronics RainMachine Mini-8 (2nd generation) uses the administrator's password hash to generate a 6-digit temporary passcode that can be used for remote and local access, aka a "Use of Password Hash Instead of Password for Authentication" issue. This is exploitable by an attacker who discovers a hash value in the rainmachine-settings.sqlite file.
References
Link | Resource |
---|---|
http://www.irongeek.com/i.php?page=videos/bsidesrdu2018/bsidesrdu-2018-07-when-it-rains-it-pours-sam-granger | Exploit Third Party Advisory |
Configurations
Configuration 1 (hide)
AND |
|
Information
Published : 2018-11-01 10:29
Updated : 2020-08-24 10:37
NVD link : CVE-2018-6011
Mitre link : CVE-2018-6011
JSON object : View
CWE
CWE-287
Improper Authentication
Products Affected
rainmachine
- mini-8_firmware
- mini-8