In the /HNAP1/SetQoSSettings message, the uplink parameter is vulnerable, and the vulnerability affects D-Link DIR-822 Rev.B 202KRb06 and DIR-822 Rev.C 3.10B06 devices. In the SetQoSSettings.php source code, the uplink parameter is saved in the /bwc/entry:1/bandwidth and /bwc/entry:2/bandwidth internal configuration memory without any regex checking. And in the bwc_tc_spq_start, bwc_tc_wfq_start, and bwc_tc_adb_start functions of the bwcsvcs.php source code, the data in /bwc/entry:1/bandwidth and /bwc/entry:2/bandwidth is used with the tc command without any regex checking. A vulnerable /HNAP1/SetQoSSettings XML message could have shell metacharacters in the uplink element such as the `telnetd` string.
References
Advertisement

NeevaHost hosting service

Configurations

Configuration 1 (hide)

AND
OR cpe:2.3:o:d-link:dir-822_firmware:3.10b06:*:*:*:*:*:*:*
cpe:2.3:o:d-link:dir-822_firmware:202krb06:*:*:*:*:*:*:*
cpe:2.3:h:d-link:dir-822:-:*:*:*:*:*:*:*

Information

Published : 2019-05-13 07:29

Updated : 2019-10-02 17:03


NVD link : CVE-2018-19989

Mitre link : CVE-2018-19989


JSON object : View

CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Advertisement

dedicated server usa

Products Affected

d-link

  • dir-822_firmware
  • dir-822