Show plain JSON{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://www.exploit-db.com/exploits/45937/", "name": "45937", "tags": ["Third Party Advisory", "VDB Entry"], "refsource": "EXPLOIT-DB"}, {"url": "http://packetstormsecurity.com/files/150619/Rockwell-Automation-Allen-Bradley-PowerMonitor-1000-Authentication-Bypass.html", "name": "http://packetstormsecurity.com/files/150619/Rockwell-Automation-Allen-Bradley-PowerMonitor-1000-Authentication-Bypass.html", "tags": ["Third Party Advisory", "VDB Entry"], "refsource": "MISC"}, {"url": "http://www.securityfocus.com/bid/106333", "name": "106333", "tags": ["VDB Entry", "Third Party Advisory"], "refsource": "BID"}, {"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-04", "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-04", "tags": ["US Government Resource", "Third Party Advisory"], "refsource": "MISC"}, {"url": "http://www.securityfocus.com/bid/108538", "name": "108538", "tags": [], "refsource": "BID"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. An unauthenticated user can add/edit/remove administrators because access control is implemented on the client side via a disabled attribute for a BUTTON element."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-287"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2018-19616", "ASSIGNER": "cve@mitre.org"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "severity": "MEDIUM", "acInsufInfo": false, "impactScore": 6.4, "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}, "baseMetricV3": {"cvssV3": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 8.1, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "HIGH", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.2}}, "publishedDate": "2018-12-26T21:29Z", "configurations": {"nodes": [{"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:rockwellautomation:powermonitor_1000_firmware:1408-em3a-ent_b:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:rockwellautomation:powermonitor_1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2020-08-24T17:37Z"}