A replay issue was discovered on Neato Botvac Connected 2.2.0 devices. Manual control mode requires authentication, but once recorded, the authentication (always transmitted in cleartext) can be replayed to /bin/webserver on port 8081. There are no nonces, and timestamps are not checked at all.
References
Link | Resource |
---|---|
https://media.ccc.de/v/2018-124-pinky-brain-are-taking-over-the-world-with-vacuum-cleaners | Exploit Third Party Advisory |
Configurations
Configuration 1 (hide)
AND |
|
Configuration 2 (hide)
AND |
|
Configuration 3 (hide)
AND |
|
Information
Published : 2018-09-18 11:29
Updated : 2020-08-24 10:37
NVD link : CVE-2018-17176
Mitre link : CVE-2018-17176
JSON object : View
CWE
CWE-294
Authentication Bypass by Capture-replay
Products Affected
neatorobotics
- botvac_d6_connected
- botvac_d4_connected
- botvac_d7_connected_firmware
- botvac_d6_connected_firmware
- botvac_d4_connected_firmware
- botvac_d7_connected