{"cve": {"data_type": "CVE", "references": {"reference_data": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf", "tags": ["Vendor Advisory"], "refsource": "CONFIRM"}, {"url": "http://www.securityfocus.com/bid/105931", "name": "105931", "tags": ["Third Party Advisory", "VDB Entry"], "refsource": "BID"}]}, "data_format": "MITRE", "description": {"description_data": [{"lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."}]}, "problemtype": {"problemtype_data": [{"description": [{"lang": "en", "value": "CWE-20"}]}]}, "data_version": "4.0", "CVE_data_meta": {"ID": "CVE-2018-13814", "ASSIGNER": "productcert@siemens.com"}}, "impact": {"baseMetricV2": {"cvssV2": {"version": "2.0", "baseScore": 6.8, "accessVector": "NETWORK", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "authentication": "NONE", "integrityImpact": "PARTIAL", "accessComplexity": "MEDIUM", "availabilityImpact": "PARTIAL", "confidentialityImpact": "PARTIAL"}, "severity": "MEDIUM", "acInsufInfo": false, "impactScore": 6.4, "obtainAllPrivilege": false, "exploitabilityScore": 8.6, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": true}, "baseMetricV3": {"cvssV3": {"scope": "UNCHANGED", "version": "3.0", "baseScore": 8.8, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "REQUIRED", "attackComplexity": "LOW", "availabilityImpact": "HIGH", "privilegesRequired": "NONE", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 2.8}}, "publishedDate": "2018-12-13T16:29Z", "configurations": {"nodes": [{"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}, {"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}, {"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*", "cpe_name": [], "vulnerable": true, "versionEndExcluding": "14.0"}]}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}, {"children": [{"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true}]}, {"children": [], "operator": "OR", "cpe_match": [{"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false}]}], "operator": "AND", "cpe_match": []}], "CVE_data_version": "4.0"}, "lastModifiedDate": "2019-10-09T23:34Z"}