After Junos OS device reboot or upgrade, the stateless firewall filter configuration may not take effect. This issue can be verified by running the command: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Note: when the issue occurs, it does not show the applied firewall filter. The correct output should show the applied firewall filter, for example: user@re0> show interfaces <interface_name> extensive | match filters" CAM destination filters: 0, CAM source filters: 0 Input Filters: FIREWAL_FILTER_NAME-<interface_name> This issue affects firewall filters for every address family. Affected releases are Juniper Networks Junos OS: 15.1R4, 15.1R5, 15.1R6 and SRs based on these MRs. 15.1X8 versions prior to 15.1X8.3.
References
Link | Resource |
---|---|
https://kb.juniper.net/JSA10859 | Vendor Advisory |
http://www.securityfocus.com/bid/104720 | Third Party Advisory VDB Entry |
http://www.securitytracker.com/id/1041315 | Third Party Advisory VDB Entry |
Configurations
Configuration 1 (hide)
|
Information
Published : 2018-07-11 11:29
Updated : 2019-10-09 16:31
NVD link : CVE-2018-0026
Mitre link : CVE-2018-0026
JSON object : View
CWE
Products Affected
juniper
- junos