Sielco Sistemi Winlog Pro SCADA before 2.07.18 and Winlog Lite SCADA before 2.07.18 do not validate the return value of the realloc function, which allows remote attackers to cause a denial of service (invalid 0x00 write operation and daemon crash) or possibly have unspecified other impact via a port-46824 TCP packet with a crafted negative integer after the opcode. NOTE: this vulnerability exists because of an incomplete fix for CVE-2012-4358.
References
Link | Resource |
---|---|
http://www.sielcosistemi.com/en/news/index.html?id=70 | |
http://aluigi.org/adv/winlog_2-adv.txt | Exploit |
http://secunia.com/advisories/49395 | Vendor Advisory |
http://www.us-cert.gov/control_systems/pdf/ICSA-12-213-01.pdf | US Government Resource |
Configurations
Configuration 1 (hide)
|
Configuration 2 (hide)
|
Information
Published : 2012-08-19 13:55
Updated : 2012-08-19 21:00
NVD link : CVE-2012-4359
Mitre link : CVE-2012-4359
JSON object : View
CWE
CWE-20
Improper Input Validation
Products Affected
sielcosistemi
- winlog_pro
- winlog_lite